Ex vivo ultrasound control of resection margins during partial nephrectomy.

Details

Serval ID
serval:BIB_0640D43C5622
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Ex vivo ultrasound control of resection margins during partial nephrectomy.
Journal
Journal of Urology
Author(s)
Doerfler A., Cerantola Y., Meuwly J.Y., Lhermitte B., Bensadoun H., Jichlinski P.
ISSN
1527-3792 (Electronic)
ISSN-L
0022-5347
Publication state
Published
Issued date
2011
Volume
186
Number
6
Pages
2188-2193
Language
english
Abstract
Purpose: Surgery remains the treatment of choice for localized renal neoplasms. While radical nephrectomy was long considered the gold standard, partial nephrectomy has equivalent oncological results for small tumors. The role of negative surgical margins continues to be debated. Intraoperative frozen section analysis is expensive and time-consuming. We assessed the feasibility of intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy and its correlation with margin status on definitive pathological evaluation.Materials and Methods: A study was done at 2 institutions from February 2008 to March 2011. Patients undergoing partial nephrectomy for T1-T2 renal tumors were included in analysis. Partial nephrectomy was done by a standardized minimal healthy tissue margin technique. After resection the specimen was kept in saline and tumor margin status was immediately determined by ex vivo ultrasound. Sequential images were obtained to evaluate the whole tumor pseudocapsule. Results were compared with margin status on definitive pathological evaluation.Results: A total of 19 men and 14 women with a mean +/- SD age of 62 +/- 11 years were included in analysis. Intraoperative ex vivo ultrasound revealed negative surgical margins in 30 cases and positive margins in 2 while it could not be done in 1. Final pathological results revealed negative margins in all except 1 case. Ultrasound sensitivity and specificity were 100% and 97%, respectively. Median ultrasound duration was 1 minute. Mean tumor and margin size was 3.6 +/- 2.2 cm and 1.5 +/- 0.7 mm, respectively.Conclusions: Intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy is feasible and efficient. Large sample studies are needed to confirm its promising accuracy to determine margin status.
Pubmed
Web of science
Create date
08/12/2011 13:07
Last modification date
20/08/2019 13:28
Usage data