Fat-free noncontrast whole-heart cardiovascular magnetic resonance imaging with fast and power-optimized off-resonant water-excitation pulses.

Details

Ressource 1Download: 39278414_BIB_045B6A1F2252.pdf (5738.49 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_045B6A1F2252
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Fat-free noncontrast whole-heart cardiovascular magnetic resonance imaging with fast and power-optimized off-resonant water-excitation pulses.
Journal
Journal of cardiovascular magnetic resonance
Author(s)
Mackowiak ALC, Piccini D., van Heeswijk R.B., Hullin R., Gräni C., Bastiaansen JAM
ISSN
1532-429X (Electronic)
ISSN-L
1097-6647
Publication state
Published
Issued date
2024
Peer-reviewed
Oui
Volume
26
Number
2
Pages
101096
Language
english
Notes
Publication types: Journal Article ; Comparative Study
Publication Status: ppublish
Abstract
Cardiovascular magnetic resonance imaging (CMR) faces challenges due to the interference of bright fat signals in visualizing structures, such as coronary arteries. Effective fat suppression is crucial, especially when using whole-heart CMR techniques. Conventional methods often fall short due to rapid fat signal recovery, leading to residual fat content hindering visualization. Water-selective off-resonant radiofrequency (RF) pulses have been proposed but come with tradeoffs between pulse duration, which increases scan time, and increased RF energy deposit, which limits their applicability due to specific absorption rate (SAR) constraints. The study introduces a lipid-insensitive binomial off-resonant (LIBOR) RF pulse, which addresses concerns about SAR and scan time, and aims to provide a comprehensive quantitative comparison with published off-resonant RF pulses for CMR at 3T.
A short (1 ms) LIBOR pulse, with reduced RF power requirements, was developed and implemented in a free-breathing respiratory-self-navigated three-dimensional radial whole-heart CMR sequence at 3T. A binomial off-resonant rectangular (BORR) pulse with matched duration, as well as previously published lipid-insensitive binomial off-resonant excitation (LIBRE) pulses (1 and 2.2 ms), were implemented and optimized for fat suppression in numerical simulations and validated in volunteers (n = 3). Whole-heart CMR was performed in volunteers (n = 10) with all four pulses. The signal-to-noise ratio (SNR) of ventricular blood, skeletal muscle, myocardium, and subcutaneous fat and the coronary vessel detection rates and sharpness were compared.
Experimental results validated numerical findings and near-homogeneous fat suppression was achieved with all four pulses. Comparing the short RF pulses (1 ms), LIBOR reduced the RF power nearly two-fold compared with LIBRE, and three-fold compared with BORR, and LIBOR significantly decreased overall fat SNR from cardiac scans, compared to LIBRE and BORR. The reduction in RF pulse duration (from 2.2 to 1 ms) shortened the whole-heart acquisition from 8.5 to 7 min. No significant differences in coronary arteries detection and sharpness were found when comparing all four pulses.
LIBOR pulses enabled whole-heart CMR under 7 min at 3T, with large volume fat signal suppression, while reducing RF power compared with LIBRE and BORR pulses. LIBOR is an excellent candidate to address SAR problems encountered in CMR sequences where fat suppression remains challenging and short RF pulses are required.
Keywords
Humans, Predictive Value of Tests, Male, Adult, Time Factors, Reproducibility of Results, Magnetic Resonance Imaging, Female, Heart/diagnostic imaging, Image Interpretation, Computer-Assisted, Healthy Volunteers, Young Adult, Adipose Tissue/diagnostic imaging, Body Water/diagnostic imaging, 3T, Fat signal suppression, MRI, Off-resonant water excitation, RF excitation pulse, SAR