Comparison of the standards of absorbed dose to graphite of the IRA and the BIPM for Co y rays

Détails

ID Serval
serval:BIB_E97F041771D2
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Comparison of the standards of absorbed dose to graphite of the IRA and the BIPM for Co y rays
Périodique
Rapport BIPM-90/9
Auteur⸱e⸱s
Perroche A. M., Gardel P.
Statut éditorial
Publié
Date de publication
01/1990
Langue
français
Résumé
A comparison between the standards of absorbed dose to graphite of the
Institut de Radiophysique Appliquee and the Bureau International des Poids
et Mesures has been performed at depths from 3 to 16 g cm-2 The ratio of
the absorbed dose rates determined by each standard is 0,997 6 at the
reference depth of 5 g cm-2