Modified cine inversion recovery pulse sequence for the quantification of myocardial T1 and gadolinium partition coefficient.

Détails

ID Serval
serval:BIB_D107BD471746
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Modified cine inversion recovery pulse sequence for the quantification of myocardial T1 and gadolinium partition coefficient.
Périodique
Journal of magnetic resonance imaging
Auteur⸱e⸱s
Milanesi M., Barison A., Positano V., Masci P.G., De Marchi D., Marinelli L., Hardy C.J., Foo T.K., Landini L., Lombardi M.
ISSN
1522-2586 (Electronic)
ISSN-L
1053-1807
Statut éditorial
Publié
Date de publication
01/2013
Peer-reviewed
Oui
Volume
37
Numéro
1
Pages
109-118
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
To optimize and validate a modified cine inversion recovery sequence (MCine-IR) for myocardial T1 quantification and gadolinium partition coefficient (λ(Gd)) estimation at 1.5 T.
The original version of the cine inversion recovery sequence was modified to allow fully transverse magnetization recovery between two successive inversion pulses. Sixty heart phases were acquired from a number of heart cycles determined on a patient heart rate basis. Phantom studies were carried out to find the optimal effective TR for myocardial and blood pool T1 quantifications in pre- and postcontrast studies. Four patients with myocardial infarct (MI) and 22 dilated cardiomyopathy (DCM) were investigated, as well as 11 healthy subjects used as controls.
Effective TR was identified to be 5000 msec and 2000 msec, respectively, for pre- and postcontrast studies. A longer precontrast (948 ± 102 msec) and shorter postcontrast (348 ± 27 msec) T1 in ischemic patients relative to DCM (815 ± 98 msec, P = 0.03 and 409 ± 42 msec, P = 0.001) were noted in delayed enhancement (DE) areas. In MI patients λ(Gd) resulted higher than in DCM in DE areas (609 ± 167 vs. 422 ± 52, P = 0.01) but lower in segments not exhibiting DE (355 ± 100 vs. 398 ± 54, P = 0.02).
It was feasible to measure T1 and λ(Gd) with MCine-IR and the results were in good agreement with the literature.

Mots-clé
Adult, Aged, Cardiomyopathy, Dilated/diagnosis, Cardiomyopathy, Dilated/pathology, Contrast Media/pharmacology, Diagnostic Imaging/methods, Female, Gadolinium/pharmacology, Heart/physiopathology, Heart Rate, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Cine/methods, Male, Middle Aged, Models, Statistical, Myocardial Infarction/diagnosis, Myocardial Infarction/pathology, Myocardium/pathology, Phantoms, Imaging
Pubmed
Web of science
Open Access
Oui
Création de la notice
25/08/2017 21:46
Dernière modification de la notice
20/08/2019 16:51
Données d'usage