Dental-CT: Bildqualität und Strahlenexposition in Abhängigkeit von den Scanparametern [Dental CT: image quality and radiation exposure in relation to scan parameters].
Détails
ID Serval
serval:BIB_912EF1746E0A
Type
Article: article d'un périodique ou d'un magazine.
Sous-type
Synthèse (review): revue aussi complète que possible des connaissances sur un sujet, rédigée à partir de l'analyse exhaustive des travaux publiés.
Collection
Publications
Institution
Titre
Dental-CT: Bildqualität und Strahlenexposition in Abhängigkeit von den Scanparametern [Dental CT: image quality and radiation exposure in relation to scan parameters].
Périodique
Röfo
ISSN
1438-9029[print], 1438-9010[linking]
Statut éditorial
Publié
Date de publication
1999
Volume
170
Numéro
2
Pages
137-144
Langue
allemand
Notes
Publication types: English Abstract ; Journal Article ; Review
Publication Status: ppublish
Publication Status: ppublish
Résumé
PURPOSE: To develop a scan protocol for dental-CT which guarantees good image quality at the lowest possible radiation dose. METHODS: In an experimental investigation Dental-CT (HSA, GE, Milwaukee, USA) of the mandible of two human skeletons positioned in a water tank were performed in order to define the most advantageous scan protocol. Tube currents ranged from 40 to 200 mA and the scan technique was modified (axial mode or helical mode with pitches of 1 to 3 and corresponding increments of 0.4 to 1.0 mm). 39 patients underwent a dental-CT with decreased current (80 mA) in the helical scan mode (pitch 2, slice thickness 1 mm). Dose measurements were performed for two different scan protocols (A: axial, 130 mAs, B: helical, 80 mA, pitch 2). RESULTS: The preliminary investigations of image quality showed only a minor effect of the applied current. For the helical scan mode, pitches of more than 2 impaired image quality. A low increment had no advantages. There were no disadvantages in clinical practice using protocol B with decreased tube current. Absorbed radiation dose of dental CT performed with protocol B was decreased to one third in comparison to protocol A. CONCLUSIONS: A scan protocol with a low tube current (e.g., 80 mA, for a rotation time of 1 s) and a helical scan mode (e.g., for a slice thickness of 1 mm with a pitch of 2 and an increment of 1 mm) is recommended for performing dental-CT.
Mots-clé
Adult, Aged, Dental Implantation, Endosseous, Female, Humans, Male, Mandible/radiography, Maxilla/radiography, Middle Aged, Phantoms, Imaging, Radiation Dosage, Radiography, Dental/instrumentation, Retrospective Studies, Scattering, Radiation, Thermoluminescent Dosimetry, Tomography, X-Ray Computed/instrumentation
Pubmed
Création de la notice
10/03/2011 15:04
Dernière modification de la notice
20/08/2019 14:54