Dental-CT: Bildqualität und Strahlenexposition in Abhängigkeit von den Scanparametern [Dental CT: image quality and radiation exposure in relation to scan parameters].

Details

Serval ID
serval:BIB_912EF1746E0A
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Title
Dental-CT: Bildqualität und Strahlenexposition in Abhängigkeit von den Scanparametern [Dental CT: image quality and radiation exposure in relation to scan parameters].
Journal
Röfo
Author(s)
Schorn C., Visser H., Hermann K.P., Alamo L., Funke M., Grabbe E.
ISSN
1438-9029[print], 1438-9010[linking]
Publication state
Published
Issued date
1999
Volume
170
Number
2
Pages
137-144
Language
german
Notes
Publication types: English Abstract ; Journal Article ; Review
Publication Status: ppublish
Abstract
PURPOSE: To develop a scan protocol for dental-CT which guarantees good image quality at the lowest possible radiation dose. METHODS: In an experimental investigation Dental-CT (HSA, GE, Milwaukee, USA) of the mandible of two human skeletons positioned in a water tank were performed in order to define the most advantageous scan protocol. Tube currents ranged from 40 to 200 mA and the scan technique was modified (axial mode or helical mode with pitches of 1 to 3 and corresponding increments of 0.4 to 1.0 mm). 39 patients underwent a dental-CT with decreased current (80 mA) in the helical scan mode (pitch 2, slice thickness 1 mm). Dose measurements were performed for two different scan protocols (A: axial, 130 mAs, B: helical, 80 mA, pitch 2). RESULTS: The preliminary investigations of image quality showed only a minor effect of the applied current. For the helical scan mode, pitches of more than 2 impaired image quality. A low increment had no advantages. There were no disadvantages in clinical practice using protocol B with decreased tube current. Absorbed radiation dose of dental CT performed with protocol B was decreased to one third in comparison to protocol A. CONCLUSIONS: A scan protocol with a low tube current (e.g., 80 mA, for a rotation time of 1 s) and a helical scan mode (e.g., for a slice thickness of 1 mm with a pitch of 2 and an increment of 1 mm) is recommended for performing dental-CT.
Keywords
Adult, Aged, Dental Implantation, Endosseous, Female, Humans, Male, Mandible/radiography, Maxilla/radiography, Middle Aged, Phantoms, Imaging, Radiation Dosage, Radiography, Dental/instrumentation, Retrospective Studies, Scattering, Radiation, Thermoluminescent Dosimetry, Tomography, X-Ray Computed/instrumentation
Pubmed
Create date
10/03/2011 15:04
Last modification date
20/08/2019 14:54
Usage data