Right coronary artery flow velocity and volume assessment with spiral K-space sampled breathhold velocity-encoded MRI at 3 tesla: accuracy and reproducibility.
Détails
Télécharger: BIB_5FBA70E5350F.P001.pdf (1295.14 [Ko])
Etat: Public
Version: de l'auteur⸱e
Etat: Public
Version: de l'auteur⸱e
ID Serval
serval:BIB_5FBA70E5350F
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Right coronary artery flow velocity and volume assessment with spiral K-space sampled breathhold velocity-encoded MRI at 3 tesla: accuracy and reproducibility.
Périodique
Journal of Magnetic Resonance Imaging
ISSN
1522-2586[electronic], 1053-1807[linking]
Statut éditorial
Publié
Date de publication
2010
Peer-reviewed
Oui
Volume
31
Numéro
5
Pages
1215-1223
Langue
anglais
Résumé
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
Mots-clé
Accuracy, Reproducibility, MRI, Coronary Flow Velocity, Phase-Contrast Flow, Signal-To-Noise, Magnetic-Resonance Angiography, Blood-Flow, Quantification, Validation, Excitation, Resolution, Vessels, Ratios