Right coronary artery flow velocity and volume assessment with spiral K-space sampled breathhold velocity-encoded MRI at 3 tesla: accuracy and reproducibility.

Détails

Ressource 1Télécharger: BIB_5FBA70E5350F.P001.pdf (1295.14 [Ko])
Etat: Public
Version: de l'auteur⸱e
ID Serval
serval:BIB_5FBA70E5350F
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Right coronary artery flow velocity and volume assessment with spiral K-space sampled breathhold velocity-encoded MRI at 3 tesla: accuracy and reproducibility.
Périodique
Journal of Magnetic Resonance Imaging
Auteur⸱e⸱s
Brandts Anne, Roes Stijntje D., Doornbos Joost, Weiss Robert G., de Roos Albert, Stuber Matthias, Westenberg Jos J. M.
ISSN
1522-2586[electronic], 1053-1807[linking]
Statut éditorial
Publié
Date de publication
2010
Peer-reviewed
Oui
Volume
31
Numéro
5
Pages
1215-1223
Langue
anglais
Résumé
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
Mots-clé
Accuracy, Reproducibility, MRI, Coronary Flow Velocity, Phase-Contrast Flow, Signal-To-Noise, Magnetic-Resonance Angiography, Blood-Flow, Quantification, Validation, Excitation, Resolution, Vessels, Ratios
Pubmed
Web of science
Création de la notice
28/05/2010 9:27
Dernière modification de la notice
20/08/2019 14:17
Données d'usage