Muscle VO2 and forearm blood flow repeatability during venous and arterial occlusions in healthy and coronary heart disease subjects

Détails

Ressource 1Demande d'une copie Sous embargo indéterminé.
Accès restreint UNIL
Etat: Public
Version: de l'auteur⸱e
Licence: Non spécifiée
ID Serval
serval:BIB_46E6417DD9AB
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Muscle VO2 and forearm blood flow repeatability during venous and arterial occlusions in healthy and coronary heart disease subjects
Périodique
Clin Hemorheol Microcirc
Auteur⸱e⸱s
Gayda M., Gremeaux V., Drigny J., Juneau M., Nigam A.
ISSN
1875-8622 (Electronic)
ISSN-L
1386-0291
Statut éditorial
Publié
Date de publication
2015
Volume
59
Numéro
2
Pages
177-83
Langue
anglais
Notes
Gayda, Mathieu
Gremeaux, Vincent
Drigny, Joffrey
Juneau, Martin
Nigam, Anil
eng
Research Support, Non-U.S. Gov't
Netherlands
Clin Hemorheol Microcirc. 2015;59(2):177-83. doi: 10.3233/CH-141836.
Résumé
This study aims were: 1) to assess forearm blood flow (FBF) and muscle oxygen consumption (mVO2) repeatability assessed with near-infra red spectroscopy (NIRS) during venous occlusions (VO) in middle aged healthy subjects and patients with stable coronary heart disease (CHD), 2) to assess the agreement between mVO2 calculated from NIRS signals during VO and arterial occlusion (AO) in 18 middle aged healthy subjects and 12 patients with CHD. FBF and mVO2 were measured using NIRS during 2 successive VO (1-min duration), followed by a 5-min AO. Repeatability for FBF and mVO2 during VO was assessed with intra class correlation (ICC), coefficient of variation (CV %) and agreement between VO and AO mVO2 was assessed with a Bland and Altman analysis. FBF and mVO2 during VO were highly reproducible in healthy (FBF: ICC 0.73, CV% 9.75; mVO2: ICC 0.89, CV% 12.6) and CHD subjects (FBF: ICC 0.95, CV% 10.26; mVO2: ICC 0.98, CV% 7.92). VO and AO mVO2 were in agreement in healthy (mean bias: 0.002 mL O2.min-1.100g-1) and CHD subjects (mean bias: 0.014 mL O2.min-1.100g-1). FBF and mVO2 measured with NIRS during VO and/or AO are highly reproducible methods to assess microvascular function in healthy subjects and stable CHD patients.
Mots-clé
Coronary Disease/*genetics, Female, Forearm/*blood supply, Hemodynamics/*physiology, Humans, Male, Middle Aged, Oxygen Consumption/physiology, Regional Blood Flow/*physiology, Near-infra red spectroscopy, agreement, healthy middle aged subjects, patients with coronary heart disease, repeatability, vascular occlusions
Pubmed
Création de la notice
26/11/2019 12:35
Dernière modification de la notice
04/05/2020 7:06
Données d'usage