The Role of 2, 4, and 5-dimensional Cardiac Flow MRI for Evaluation of Valvulopathies: A Literature Review.

Details

Ressource 1Download: 39501599.pdf (458.28 [Ko])
State: Public
Version: Final published version
License: CC BY 4.0
Serval ID
serval:BIB_91302E80D3BA
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Institution
Title
The Role of 2, 4, and 5-dimensional Cardiac Flow MRI for Evaluation of Valvulopathies: A Literature Review.
Journal
Echocardiography
Author(s)
Fässler S., Falcão MBL, de Marchi S.F., Roy C.W., Rutz T.
ISSN
1540-8175 (Electronic)
ISSN-L
0742-2822
Publication state
Published
Issued date
11/2024
Peer-reviewed
Oui
Volume
41
Number
11
Pages
e70005
Language
english
Notes
Publication types: Journal Article ; Review
Publication Status: ppublish
Abstract
Two-dimensional phase-contrast magnetic resonance imaging (2D flow MRI) and its multidimensional alternatives, 4D and 5D flow MRI, measure blood flow in the heart and great vessels. While 2D flow MRI is the standard technique, it has limitations regarding need for precise image plane prescribing and long scan time. In contrast, 4D and 5D flow MRI acquire 3D volumes, enabling retrospective assessment of all vessels. This review evaluates these three techniques for quantification of blood flow of the aortic and pulmonary valves in congenital heart disease.
A systematic literature search was conducted in August 2024 using the PUBMED database, including articles comparing 2D, 4D, and 5D flow MRI.
Fifteen articles comparing 2D and 4D, one comparing 2D and 5D and three articles comparing 4D and 5D flow MRI were included. No study compared all three techniques. 2D, 4D and 5D flow MRI demonstrated a good agreement for flow quantification. 4D flow MRI, however, tends to present a better accuracy and internal consistency than 2D flow MRI for determination of peak velocities and flow in stenotic lesions, particularly when comparing velocities to echocardiography. 4D and 5D flow MRI are associated with shorter scan times than 2D flow MRI.
4D and 5D flow MRI appear to offer promising alternatives to 2D flow MRI with the advantage of reduced scan times. Larger and prospective studies including echocardiography are needed to evaluate the potential of 4D and 5D to replace 2D flow MRI for flow quantification and peak velocity determination.
Keywords
Humans, Blood Flow Velocity/physiology, Heart Valve Diseases/physiopathology, Heart Valve Diseases/diagnostic imaging, Heart Defects, Congenital/diagnostic imaging, Heart Defects, Congenital/physiopathology, Magnetic Resonance Imaging/methods, Aortic Valve/diagnostic imaging, Aortic Valve/physiopathology, Pulmonary Valve/diagnostic imaging, Pulmonary Valve/physiopathology, Imaging, Three-Dimensional/methods, 2D cardiac flow MRI, 4D cardiac flow MRI, 5D cardiac flow MRI, cardiac magnetic resonance imaging