Biomechanical stability of a posterior-alone fixation technique after craniovertebral junction realignment.

Details

Serval ID
serval:BIB_EACE1083804F
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Biomechanical stability of a posterior-alone fixation technique after craniovertebral junction realignment.
Journal
World Neurosurgery
Author(s)
Daniel R.T., Muzumdar A., Ingalhalikar A., Moldavsky M., Khalil S.
ISSN
1878-8750 (Print)
Publication state
Published
Issued date
2012
Volume
77
Number
2
Pages
357-361
Language
english
Notes
Publication types: Journal ArticlePublication Status: ppublish
Abstract
OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.
Pubmed
Web of science
Create date
19/05/2012 19:56
Last modification date
20/08/2019 17:13
Usage data