A Smart Solution for Solving Acute Angulations during Frozen Elephant Trunk Implantation.

Details

Serval ID
serval:BIB_DC33F4B9CBD7
Type
Article: article from journal or magazin.
Publication sub-type
Case report (case report): feedback on an observation with a short commentary.
Collection
Publications
Institution
Title
A Smart Solution for Solving Acute Angulations during Frozen Elephant Trunk Implantation.
Journal
Thoracic and Cardiovascular Surgeon
Author(s)
Czerny M., Grabenwöger M., von Segesser L.
ISSN
1439-1902 (Electronic)
ISSN-L
0171-6425
Publication state
Published
Issued date
2016
Peer-reviewed
Oui
Volume
64
Number
2
Pages
137-138
Language
english
Abstract
Acute angulations of native thoracic aortic segments affect treatment strategies for acute and chronic thoracic aortic pathology. These angulations might present an issue not only in segments where thoracic endovascular aortic repair is planned but also in segments where open repair is intended. Consequently, clinical scenarios arise where there is need for adapting strategies in frozen elephant trunk implantation. In this conceptual report, we do describe a technical modification to solve this issue.