Intraprocedural 3D Quantification of Lipiodol Deposition on Cone-Beam CT Predicts Tumor Response After Transarterial Chemoembolization in Patients with Hepatocellular Carcinoma.

Details

Ressource 1Request a copyDownload: BIB_4CFA1C0F625D.P001.pdf (2847.10 [Ko])
State: Deleted
Version: author
Serval ID
serval:BIB_4CFA1C0F625D
Type
Article: article from journal or magazin.
Collection
Publications
Title
Intraprocedural 3D Quantification of Lipiodol Deposition on Cone-Beam CT Predicts Tumor Response After Transarterial Chemoembolization in Patients with Hepatocellular Carcinoma.
Journal
Cardiovascular and Interventional Radiology
Author(s)
Wang Z., Chen R., Duran R., Zhao Y., Yenokyan G., Chapiro J., Schernthaner R., Radaelli A., Lin M., Geschwind J.F.
ISSN
1432-086X (Electronic)
ISSN-L
0174-1551
Publication state
Published
Issued date
2015
Peer-reviewed
Oui
Volume
38
Number
6
Pages
1548-1556
Language
english
Abstract
PURPOSE: To evaluate whether intraprocedural 3D quantification of Lipiodol deposition on cone-beam computed tomography (CBCT) can predict tumor response on follow-up contrast-enhanced magnetic resonance imaging (CE-MRI) in patients with hepatocellular carcinoma (HCC) treated with conventional transarterial chemoembolization (cTACE).
MATERIALS AND METHODS: This IRB approved, retrospective analysis included 36 patients with 51 HCC target lesions, who underwent cTACE with CBCT. CE-MRI was acquired at baseline and 1 month after cTACE. Overall tumor volumes as well as intratumoral Lipiodol volumes on CBCT were measured and compared with the overall and necrotic (non-enhancing) tumor volumes on CE-MRI using the paired student's t test. Tumor response on CE-MRI was assessed using modified response evaluation criteria in solid tumors (mRECIST). A linear regression model was used to correlate tumor volumes, Lipiodol volumes, and the percentage of Lipiodol deposition on CBCT with the corresponding parameters on CE-MRI. Nonparametric spearman rank-order correlation and trend test were used to correlate the percentage of Lipiodol deposition in the tumor with tumor response.
RESULT: A strong correlation between overall tumor volumes on CBCT and CE-MRI was observed (R(2) = 0.986). In addition, a strong correlation was obtained between the volume of Lipiodol deposition on CBCT and tumor necrosis (in cm(3)) on CE-MRI (R(2) = 0.960), and between the percentage of Lipiodol deposition and tumor necrosis (R(2) = 0.979). Importantly, the extent of Lipiodol deposition (in percentage of total tumor volume) correlated strongly with tumor response on CE-MRI (Spearman rho = 0.84, p < 0.001).
CONCLUSIONS: Intraprocedural 3D quantification of Lipiodol deposition on CBCT can be used to predict tumor response on follow-up CE-MRI.