Controlled contrast transcranial Doppler and arterial blood gas analysis to quantify shunt through patent foramen ovale.

Details

Serval ID
serval:BIB_49A9819BDDB3
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Controlled contrast transcranial Doppler and arterial blood gas analysis to quantify shunt through patent foramen ovale.
Journal
Stroke
Author(s)
Devuyst G., Piechowski-Józwiak B., Karapanayiotides T., Fitting J.W., Kémeny V., Hirt L., Urbano L.A., Arnold P., van Melle G., Despland P.A., Bogousslavsky J.
ISSN
1524-4628[electronic]
Publication state
Published
Issued date
2004
Volume
35
Number
4
Pages
859-863
Language
english
Notes
Publication types: Comparative Study ; Evaluation Studies ; Journal Article ;
Abstract
BACKGROUND AND PURPOSE: A right-to-left shunt can be identified by contrast transcranial Doppler ultrasonography (c-TCD) at rest and/or after a Valsalva maneuver (VM) or by arterial blood gas (ABG) measurement. We assessed the influence of controlled strain pressures and durations during VM on the right-to-left passage of microbubbles, on which depends the shunt classification by c-TCD, and correlated it with the right-to-left shunt evaluation by ABG measurements in stroke patients with patent foramen ovale (PFO). METHODS: We evaluated 40 stroke patients with transesophageal echocardiography-documented PFO. The microbubbles were recorded with TCD at rest and after 4 different VM conditions with controlled duration and target strain pressures (duration in seconds and pressure in cm H2O, respectively): V5-20, V10-20, V5-40, and V10-40. The ABG analysis was performed after pure oxygen breathing in 34 patients, and the shunt was calculated as percentage of cardiac output. RESULTS: Among all VM conditions, V5-40 and V10-40 yielded the greatest median number of microbubbles (84 and 95, respectively; P<0.01). A significantly larger number of microbubbles were detected in V5-40 than in V5-20 (P<0.001) and in V10-40 than in V10-20 (P<0.01). ABG was not sensitive enough to detect a shunt in 31 patients. CONCLUSIONS: The increase of VM expiratory pressure magnifies the number of microbubbles irrespective of the strain duration. Because the right-to-left shunt classification in PFO is based on the number of microbubbles, a controlled VM pressure is advised for a reproducible shunt assessment. The ABG measurement is not sensitive enough for shunt assessment in stroke patients with PFO.
Keywords
Adult, Aged, Arteries/chemistry, Blood Gas Analysis, Cerebrovascular Circulation, Female, Heart Septal Defects, Atrial/complications, Heart Septal Defects, Atrial/diagnosis, Humans, Male, Middle Aged, Prospective Studies, Stroke/etiology, Ultrasonography, Doppler, Transcranial, Valsalva Maneuver