Mise en place d’une politique de qualité et de sécurité lors de l’installation d’un nouvel équipement dans un service de radiothérapie [Quality and safety policy implementation for a new radiotherapy device]

Details

Serval ID
serval:BIB_3663CB8065E5
Type
Article: article from journal or magazin.
Publication sub-type
Review (review): journal as complete as possible of one specific subject, written based on exhaustive analyses from published work.
Collection
Publications
Institution
Title
Mise en place d’une politique de qualité et de sécurité lors de l’installation d’un nouvel équipement dans un service de radiothérapie [Quality and safety policy implementation for a new radiotherapy device]
Journal
Cancer radiotherapie
Author(s)
Martin C., Jumeau R., Blais E., Canova C.H., Klausner G., Dumas R., Rouger A., Pariente F., Lyothier A., Slama Y., Dol J., Perret J., Jenny C., Chea M., Pasdeloup F., Maingon P., Troussier I.
ISSN
1769-6658 (Electronic)
ISSN-L
1278-3218
Publication state
Published
Issued date
02/2019
Peer-reviewed
Oui
Volume
23
Number
1
Pages
50-57
Language
french
Notes
Publication types: Journal Article ; Review
Publication Status: ppublish
Abstract
Modern radiotherapy techniques (intensity-modulated radiotherapy, volumetric-modulated arctherapy, image-guided radiotherapy) or stereotactic radiotherapy are in expansion in most French cancer centres. The arrival of such techniques requires updates of existing equipment or implementation of new radiotherapy devices with adapted options. With the arrival of these new devices, there is a need to develop a quality and safety policy. This is necessary to ease the process from the setup to the first treated patient. The quality and safety policy is maintained to ensure the quality assurance of the radiotherapy equipment. We conducted a review of the literature on the quality and safety policy in the French legal framework that can be proposed when implementing a new radiotherapy device.
Keywords
Equipment and Supplies, Humans, Organizational Policy, Quality Assurance, Health Care, Quality Control, Radiotherapy/instrumentation, Risk Management, Safety Management, Staff Development, Accélérateurs linéaires, Analyse a posteriori des risques, Analyse des risques, Arc-thérapie volumétrique modulée, Culture de qualité et sûreté, Formations, Intensity-modulated radiotherapy, Quality and safety policy, Radiotherapy device, Radiothérapie par modulation d’intensité, Risk analysis, Stereotactic radiotherapy, Stéréotaxie, Training, Volumetric-modulated arctherapy