Diagnostic performance of (99m)Tc-MIBI scan in predicting the malignancy of thyroid nodules: a meta-analysis.

Details

Serval ID
serval:BIB_1234E543479B
Type
Article: article from journal or magazin.
Collection
Publications
Title
Diagnostic performance of (99m)Tc-MIBI scan in predicting the malignancy of thyroid nodules: a meta-analysis.
Journal
Endocrine
Author(s)
Treglia G., Caldarella C., Saggiorato E., Ceriani L., Orlandi F., Salvatori M., Giovanella L.
ISSN
1559-0100 (Electronic)
ISSN-L
1355-008X
Publication state
Published
Issued date
08/2013
Peer-reviewed
Oui
Volume
44
Number
1
Pages
70-78
Language
english
Notes
Publication types: Journal Article ; Meta-Analysis
Publication Status: ppublish
Abstract
Several studies have investigated the diagnostic performance of (99m)Tc-MIBI scan in the evaluation of thyroid nodules suspicious for malignancy with conflicting results. The aim of our study is to meta-analyze published data on this topic. A comprehensive literature search of studies published through December 2012 regarding the diagnostic performance of (99m)Tc-MIBI scan in the evaluation of thyroid nodules suspicious for malignancy was carried out. Pooled sensitivity and specificity of (99m)Tc-MIBI scan on a per lesion-based analysis and the area under the ROC curve were calculated. Pathological reports of thyroid nodules were considered as reference standard. Twenty-one studies were included in the meta-analysis. Pooled sensitivity and specificity of (99m)Tc-MIBI scan in detecting malignant thyroid nodules were 85.1 % [95 % confidence interval (95 % CI): 81.1-88.5 %] and 45.7 % (95 % CI: 42.7-48.7 %), respectively, on a per lesion-based analysis, irrespective of eventual results of previous technetium pertechnetate ((99m)TcO4) or iodine-123 ((123)I) scan. The area under the ROC curve was 0.78. A sub-analysis restricted to data on hypofunctioning nodules on (99m)TcO4 or (123)I scans was performed: pooled sensitivity and specificity of (99m)Tc-MIBI scan in these nodules were 82.1 % (95 % CI: 77.2-86.3 %) and 62.8 % (95 % CI: 58.9-66.7 %), respectively, on a per lesion-based analysis. The area under the ROC curve was 0.81. (99m)Tc-MIBI scan is a sensitive diagnostic tool in predicting the malignancy of thyroid nodules. Therefore, this imaging method could be helpful in patients with thyroid nodules in which malignancy is suspected on the basis of conventional diagnostic techniques. Higher specificity can be reached when hypofunctioning thyroid nodules are considered.

Keywords
Adult, Diagnosis, Differential, Diagnostic Techniques, Endocrine/standards, Female, Humans, Male, Middle Aged, ROC Curve, Radionuclide Imaging, Review Literature as Topic, Sensitivity and Specificity, Technetium Tc 99m Sestamibi, Thyroid Neoplasms/diagnostic imaging, Thyroid Nodule/diagnostic imaging
Pubmed
Web of science
Create date
20/08/2017 20:58
Last modification date
20/08/2019 13:40
Usage data