Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis.

Details

Ressource 1Request a copy Under indefinite embargo.
UNIL restricted access
State: Public
Version: author
License: CC BY 4.0
Serval ID
serval:BIB_07658DAE0810
Type
Article: article from journal or magazin.
Collection
Publications
Institution
Title
Reference Ranges of 8-Isoprostane Concentrations in Exhaled Breath Condensate (EBC): A Systematic Review and Meta-Analysis.
Journal
International journal of molecular sciences
Author(s)
Shoman Y., Wild P., Hemmendinger M., Graille M., Sauvain J.J., Hopf N.B., Guseva Canu I.
ISSN
1422-0067 (Electronic)
ISSN-L
1422-0067
Publication state
Published
Issued date
28/05/2020
Peer-reviewed
Oui
Volume
21
Number
11
Pages
3822
Language
english
Notes
Publication types: Journal Article ; Meta-Analysis ; Systematic Review
Publication Status: epublish
Abstract
Isoprostanes are physiopathologic mediators of oxidative stress, resulting in lipid peroxidation. 8-isoprostane seems particularly useful for measuring oxidative stress damage. However, no reference range values are available for 8-isoprosante in exhaled breath condensate (EBC) of healthy adults, enabling its meaningful interpretation as a biomarker. We conducted this systematic review and meta-analysis according to the protocol following PROSPERO (CRD42020146623). After searching and analyzing the literature, we included 86 studies. After their qualitative synthesis and risk of bias assessment, 52 studies were included in meta-analysis. The latter focused on studies using immunological analytical methods and investigated how the concentrations of 8-isoprostane differ based on gender. We found that gender had no significant effect in 8-isoprostane concentration. Among other studied factors, such as individual characteristics and factors related to EBC collection, only the device used for EBC collection significantly affected measured 8-isoprostane concentrations. However, adjustment for the factors related to EBC collection, yielded uncertainty whether this effect is due to the device itself or to the other factors. Given this uncertainty, we estimated the reference range values of 8-isoprostane stratified by gender and EBC collection device. A better standardization of EBC collection seems necessary; as well more studies using chemical analytical methods to extend this investigation.
Keywords
Asthma/diagnosis, Biomarkers/analysis, Breath Tests/instrumentation, Dinoprost/analogs & derivatives, Dinoprost/analysis, Exhalation, Female, Healthy Volunteers, Humans, Inflammation, Lung/drug effects, Male, Nitric Oxide/analysis, Oxidative Stress, Reference Values, Sex Factors, 8-isoprostane, baseline value, exhaled air, exposure, gender, healthy adult, inflammation, lung, oxidative stress, reference range
Pubmed
Web of science
Open Access
Yes
Create date
10/06/2020 21:50
Last modification date
25/04/2021 6:34
Usage data