Raman spectroscopy and microspectroscopy of reactive dyes on cotton fibres: analysis and detection limits
Détails
ID Serval
serval:BIB_FE50AFC4D5C1
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Raman spectroscopy and microspectroscopy of reactive dyes on cotton fibres: analysis and detection limits
Périodique
Forensic Science International
ISSN
1872-6283 ; 0379-0738
ISSN-L
0379-0738
Statut éditorial
Publié
Date de publication
10/2012
Peer-reviewed
Oui
Volume
222
Numéro
1-3
Pages
200-207
Langue
anglais
Résumé
A collaborative study on Raman spectroscopy and microspectrophotometry (MSP) was carried out by
members of the ENFSI (European Network of Forensic Science Institutes) European Fibres Group (EFG) on
different dyed cotton fabrics. The detection limits of the two methods were tested on two cotton sets
with a dye concentration ranging from 0.5 to 0.005% (w/w).
This survey shows that it is possible to detect the presence of dye in fibres with concentrations below
that detectable by the traditional methods of light microscopy and microspectrophotometry (MSP). The
MSP detection limit for the dyes used in this study was found to be a concentration of 0.5% (w/w). At this
concentration, the fibres appear colourless with light microscopy. Raman spectroscopy clearly shows a
higher potential to detect concentrations of dyes as low as 0.05% for the yellow dye RY145 and 0.005% for
the blue dye RB221. This detection limit was found to depend both on the chemical composition of the
dye itself and on the analytical conditions, particularly the laser wavelength.
Furthermore, analysis of binary mixtures of dyes showed that while the minor dye was detected at
1.5% (w/w) (30% of the total dye concentration) using microspectrophotometry, it was detected at a level
as low as 0.05% (w/w) (10% of the total dye concentration) using Raman spectroscopy.
This work also highlights the importance of a flexible Raman instrument equipped with several lasers
at different wavelengths for the analysis of dyed fibres. The operator and the set up of the analytical
conditions are also of prime importance in order to obtain high quality spectra. Changing the laser
wavelength is important to detect different dyes in a mixture.
members of the ENFSI (European Network of Forensic Science Institutes) European Fibres Group (EFG) on
different dyed cotton fabrics. The detection limits of the two methods were tested on two cotton sets
with a dye concentration ranging from 0.5 to 0.005% (w/w).
This survey shows that it is possible to detect the presence of dye in fibres with concentrations below
that detectable by the traditional methods of light microscopy and microspectrophotometry (MSP). The
MSP detection limit for the dyes used in this study was found to be a concentration of 0.5% (w/w). At this
concentration, the fibres appear colourless with light microscopy. Raman spectroscopy clearly shows a
higher potential to detect concentrations of dyes as low as 0.05% for the yellow dye RY145 and 0.005% for
the blue dye RB221. This detection limit was found to depend both on the chemical composition of the
dye itself and on the analytical conditions, particularly the laser wavelength.
Furthermore, analysis of binary mixtures of dyes showed that while the minor dye was detected at
1.5% (w/w) (30% of the total dye concentration) using microspectrophotometry, it was detected at a level
as low as 0.05% (w/w) (10% of the total dye concentration) using Raman spectroscopy.
This work also highlights the importance of a flexible Raman instrument equipped with several lasers
at different wavelengths for the analysis of dyed fibres. The operator and the set up of the analytical
conditions are also of prime importance in order to obtain high quality spectra. Changing the laser
wavelength is important to detect different dyes in a mixture.
Mots-clé
Forensic science Raman spectroscopy MSP Microscopy Cotton fibres Reactive dyes Detection limit
Création de la notice
04/10/2012 6:21
Dernière modification de la notice
20/08/2019 16:28