Medial migration of lag screw after gamma nailing.

Détails

ID Serval
serval:BIB_F7E61BA60CA5
Type
Article: article d'un périodique ou d'un magazine.
Sous-type
Etude de cas (case report): rapporte une observation et la commente brièvement.
Collection
Publications
Institution
Titre
Medial migration of lag screw after gamma nailing.
Périodique
Injury
Auteur⸱e⸱s
Thein E., De Cannière A., Burn A., Borens O.
ISSN
1879-0267 (Electronic)
ISSN-L
0020-1383
Statut éditorial
Publié
Date de publication
2014
Peer-reviewed
Oui
Volume
45
Numéro
8
Pages
1275-1279
Langue
anglais
Notes
Publication types: Journal Article Publication Status: ppublish PDF: Case report
Résumé
Fractures of the proximal femur are common in the elderly population. Intramedullary nailing has become the standard treatment for intertrochanteric fractures although several extramedullary implants (e.g. dynamic hip screw (DHS), blade plate, locking compression plate (LCP), etc.) exist. However, despite this being a very common operation in traumatology, there are numerous associated complications. We report the rare complication of the migration of the medial lag screw into the pelvis at five and a half weeks postoperatively. The implant was removed and replaced by a total hip arthroplasty with simultaneous grafting of the acetabular defect and strapping of the greater trochanter. The evolution was favourable. We also present a review of the literature and analyze our case.