Use of partially covered and uncovered metallic prosthesis for endoscopic ultrasound-guided hepaticogastrostomy: Results of a retrospective monocentric study.

Détails

ID Serval
serval:BIB_F6E2FED97F62
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Use of partially covered and uncovered metallic prosthesis for endoscopic ultrasound-guided hepaticogastrostomy: Results of a retrospective monocentric study.
Périodique
Endoscopic ultrasound
Auteur⸱e⸱s
De Cassan C., Bories E., Pesenti C., Caillol F., Godat S., Ratone J.P., Delpero J.R., Ewald J., Giovannini M.
ISSN
2303-9027 (Print)
ISSN-L
2226-7190
Statut éditorial
Publié
Date de publication
2017
Peer-reviewed
Oui
Volume
6
Numéro
5
Pages
329-335
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) represents an option to treat obstructive jaundice when endoscopic retrograde cholangiopancreatography (ERCP) fails. The success rate of this procedure has been shown to be very high. Up to now, plastic and self-expandable metallic stents (SEMSs) have been employed, each of them presenting some limitations. The aims of this study were to evaluate the technical and functional success rates of EUS-HGS using a dedicated biliary SEMS with a half-covered part (Giobor® stent).
We retrospectively reviewed data of patients, who underwent EUS-HGS at our center, with at least 6 months of follow-up. Demographic, clinical, and laboratory data were extracted from the patient's charts and electronic records. Technical success rate was defined as the successful passage of the Giobor stent across the stomach, along with the flow of contrast medium and/or bile through the stent. Functional success rate was considered achieved when the decrease of bilirubin value of at least 25% within the 1st week was obtained. The rate of early and late complications was assessed.
A total of 41 patients were included (21F/20M, [mean age 66, range 45-85]). Technical success rate was obtained in 37 (90.2%) of patients. Functional success rate, analyzable in 29 patients, occurred in 65%. Between the 37 patients in whom HGS was technically feasible, 13 patients (31.7%) presented an early complication, mostly infective. At 6-month follow-up, 10/37 patients (27.0%) required a new biliary drainage (BD) and 11/37 (29.7%) died because of their disease.
EUS-HGS using Giobor® stent is technically feasible, clinical effective, safe, and may be an alternative to percutaneous transhepatic BD in case of ERCP failure for biliary decompression.
Pubmed
Web of science
Création de la notice
07/10/2019 14:46
Dernière modification de la notice
01/11/2019 6:26
Données d'usage