Outcome of right ventricular assist device implantation following left ventricular assist device implantation: Systematic review and meta-analysis.

Détails

Ressource 1Télécharger: 34112048_BIB_F64AE940AE20.pdf (1135.40 [Ko])
Etat: Public
Version: Final published version
Licence: CC BY 4.0
ID Serval
serval:BIB_F64AE940AE20
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Outcome of right ventricular assist device implantation following left ventricular assist device implantation: Systematic review and meta-analysis.
Périodique
Perfusion
Auteur⸱e⸱s
Reid G., Mork C., Gahl B., Appenzeller-Herzog C., von Segesser L.K., Eckstein F., Berdajs D.A.
ISSN
1477-111X (Electronic)
ISSN-L
0267-6591
Statut éditorial
Publié
Date de publication
11/2022
Peer-reviewed
Oui
Volume
37
Numéro
8
Pages
773-784
Langue
anglais
Notes
Publication types: Meta-Analysis ; Systematic Review ; Journal Article ; Review
Publication Status: ppublish
Résumé
The main aim was a systematic evaluation of the current evidence on outcomes for patients undergoing right ventricular assist device (RVAD) implantation following left ventricular assist device (LVAD) implantation.
This systematic review was registered on PROSPERO (CRD42019130131). Reports evaluating in-hospital as well as follow-up outcome in LVAD and LVAD/RVAD implantation were identified through Ovid Medline, Web of Science and EMBASE. The primary endpoint was mortality at the hospital stay and at follow-up. Pooled incidence of defined endpoints was calculated by using random effects models.
A total of 35 retrospective studies that included 3260 patients were analyzed. 30 days mortality was in favour of isolated LVAD implantation 6.74% (1.98-11.5%) versus 31.9% (19.78-44.02%) p = 0.001 in LVAD with temporary need for RVAD. During the hospital stay the incidence of major bleeding was 18.7% (18.2-19.4%) versus 40.0% (36.3-48.8%) and stroke rate was 5.6% (5.4-5.8%) versus 20.9% (16.8-28.3%) and was in favour of isolated LVAD implantation. Mortality reported at short-term as well at long-term was 19.66% (CI 15.73-23.59%) and 33.90% (CI 8.84-59.96%) in LVAD respectively versus 45.35% (CI 35.31-55.4%) p ⩽ 0.001 and 48.23% (CI 16.01-80.45%) p = 0.686 in LVAD/RVAD group respectively.
Implantation of a temporary RVAD is allied with a worse outcome during the primary hospitalization and at follow-up. Compared to isolated LVAD support, biventricular mechanical circulatory support leads to an elevated mortality and higher incidence of adverse events such as bleeding and stroke.
Mots-clé
Humans, Heart-Assist Devices/adverse effects, Ventricular Dysfunction, Right/etiology, Heart Failure/surgery, Heart Failure/etiology, Retrospective Studies, Treatment Outcome, Hemorrhage/etiology, left ventricular assist device, right heart failure, right ventricular assist device
Pubmed
Web of science
Open Access
Oui
Création de la notice
28/06/2021 11:42
Dernière modification de la notice
23/01/2024 7:37
Données d'usage