Determination of dextromoramide by capillary gas chromatography and electron impact mass spectrometry.

Détails

ID Serval
serval:BIB_F5735203F986
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Determination of dextromoramide by capillary gas chromatography and electron impact mass spectrometry.
Périodique
Journal of Analytical Toxicology
Auteur⸱e⸱s
Kintz P., Mangin P., Lugnier A.A., Chaumont A.J.
ISSN
0146-4760[print], 0146-4760[linking]
Statut éditorial
Publié
Date de publication
1990
Volume
14
Numéro
4
Pages
252-253
Langue
anglais
Résumé
A sensitive and specific quantitative assay for the determination of dextromoramide in human fluids and tissues is described. Dextromoramide and an internal standard, SKF 525 A, are isolated by a basic extraction and back-extraction process. The final extract is separated on a 25-m capillary column B.P. 1 and drugs are detected by selected ion monitoring at m/z 100 and m/z 86 for dextromoramide and the internal standard, respectively. The minimum detectable quantities are 0.5 and 0.3 ng/mL, for dextromoramide in plasma and urine, respectively. Coefficients of variation for within-run data were less than 6%.
Mots-clé
Dextromoramide/blood, Dextromoramide/metabolism, Gas Chromatography-Mass Spectrometry/methods, Humans, Reproducibility of Results