Interobserver and intraobserver variability in detection of patent foramen ovale and atrial septal aneurysm with transesophageal echocardiography

Détails

ID Serval
serval:BIB_F471DB8572B8
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Interobserver and intraobserver variability in detection of patent foramen ovale and atrial septal aneurysm with transesophageal echocardiography
Périodique
Journal of the American Society of Echocardiography
Auteur⸱e⸱s
Cabanes  L., Coste  J., Derumeaux  G., Jeanrenaud  X., Lamy  C., Zuber  M., Mas  J. L.
ISSN
0894-7317 (Print)
Statut éditorial
Publié
Date de publication
05/2002
Volume
15
Numéro
5
Pages
441-6
Notes
Journal Article
Research Support, Non-U.S. Gov't --- Old month value: May
Résumé
BACKGROUND: An accurate diagnosis of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) may be of decisional importance in the management of patients with ischemic stroke. Very few studies have been devoted to observer agreement in the diagnosis of these atrial septum abnormalities using contrast transesophageal echocardiography, which is considered as the method of choice for the diagnosis. The aim of this study was to assess interobserver and intraobserver variability in the diagnosis of PFO and ASA with contrast echocardiography. METHODS: Three sonographers independently reviewed 100 contrast studies stored on videotape on 2 occasions each. The interobserver and intraobserver variability was assessed by calculating kappa statistics. RESULTS: The overall interobserver and intraobserver kappa values for the assessment of degree of shunting through a PFO were 0.77 (first and second reading) and 0.82, respectively. The best kappa statistics were obtained when no and small shunts (less than 10 microbubbles) were pooled and compared with larger shunts. For the diagnosis of ASA, the overall interobserver kappa value was 0.45 for the first reading and 0.71 for the second reading, whereas the overall intraobserver kappa value was 0.74. CONCLUSION: Interobserver and intraobserver agreements for the diagnosis of PFO and ASA by transesophageal echocardiography are not perfect and need to be improved, particularly for ASA. This variability has to be taken into account when deciding on a potential risky treatment to prevent recurrent strokes.
Mots-clé
Adult *Echocardiography, Transesophageal Female Heart Aneurysm/*ultrasonography Heart Atria Heart Septal Defects, Atrial/*ultrasonography *Heart Septum Humans Male Observer Variation Video Recording
Pubmed
Web of science
Création de la notice
28/01/2008 11:00
Dernière modification de la notice
20/08/2019 17:21
Données d'usage