Impact of aortic root annuloplasty on 3D aortic root geometry.

Détails

ID Serval
serval:BIB_EEA54ACDF90F
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Impact of aortic root annuloplasty on 3D aortic root geometry.
Périodique
The Journal of surgical research
Auteur⸱e⸱s
Berdajs D., Mosbahi S., Eckstein F., Reuthebuch O., Grapow M., Ferrari E., von Segesser L.K.
ISSN
1095-8673 (Electronic)
ISSN-L
0022-4804
Statut éditorial
Publié
Date de publication
05/2018
Peer-reviewed
Oui
Volume
225
Pages
45-53
Langue
anglais
Notes
Publication types: Comparative Study ; Journal Article
Publication Status: ppublish
Résumé
The aim was to evaluate the impact of aortic root (AoR) annuloplasty on 3D AoR deformation.
In experimental setup, Yacoub procedure and Yacoub with annuloplasty were performed. Results were compared to native AoR. In each AoR modality, six microsonometric (2 mm, 200 Hz) crystals were implanted at the sinotubular junction (STJ) and at the AoR base (AoB). 3D deformation of the AoR was determined by AoR tilt (α) and rotation (β) angle changes.
Tilt angle in Yacoub AoR with annuloplasty and in Yacoub AoR was maximal at ejection, 26.71 ± 0.18° and 24.91 ± 0.13°, respectively, and minimal at diastole, 25.34 ± 0.15° and 21.90 ± 0.15°, respectively. Rotation angle in Yacoub AoR with and without annuloplasty was maximal at ejection, 27.04 ± 0.25° and 23.53 ± 0.54°, respectively, and minimal at diastole, 24.84 ± 0.14° and 21.62 ± 0.16°, respectively. In native AoR, tilt angle and rotation were minimal at ejection, 14.34 ± 0.81° and 18.1 ± 3.20°, respectively, and maximal at diastole, 18.78 ± 0.84° and 21.23 ± 021°, respectively. AoB and STJ had maximal expansion at ejection; 2.59 ± 2.40% and 6.05 ± 0.66 for Yacoub and 3.75 ± 0.66% and 3.08 ± 0.24% for Yacoub with annuloplasty. In native AoR, the expansion at ejection for AoB was 7.13 ± 2.68% and for STJ was 16.42 ± 0.63%.
AoB annuloplasty reduces AoB deformation and has an impact on STJ dynamics. In both the Yacoub AoR modalities, during ejection, the AoR takes on more of a cone-like geometry, whereas in native AoR, it is of a cylinder-like shape.
Mots-clé
Animals, Aorta/anatomy & histology, Aorta/diagnostic imaging, Aortic Valve/surgery, Aortic Valve Insufficiency/surgery, Cardiac Valve Annuloplasty/adverse effects, Cardiac Valve Annuloplasty/methods, Models, Anatomic, Models, Animal, Sus scrofa, Treatment Outcome, Ultrasonography, Aortic root, Aortic root geometry, Aortic root reconstruction