Low-cost MR-compatible moving heart phantom.

Détails

ID Serval
serval:BIB_E9EB5F1C1A1D
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Low-cost MR-compatible moving heart phantom.
Périodique
Journal of Cardiovascular Magnetic Resonance
Auteur⸱e⸱s
Huber M.E., Stuber M., Botnar R.M., Boesiger P., Manning W.J.
ISSN
1097-6647[print], 1097-6647[linking]
Statut éditorial
Publié
Date de publication
2000
Volume
2
Numéro
3
Pages
181-187
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.
Mots-clé
Artifacts, Equipment Design, Heart/physiology, Humans, Magnetic Resonance Imaging/instrumentation, Models, Structural, Phantoms, Imaging, Respiratory Physiological Phenomena
Pubmed
Web of science
Création de la notice
02/03/2010 17:04
Dernière modification de la notice
20/08/2019 17:12
Données d'usage