Stereo electroencephalography-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) in drug-resistant focal epilepsy: Results from a 10-year experience.

Détails

ID Serval
serval:BIB_E906C366887F
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Stereo electroencephalography-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) in drug-resistant focal epilepsy: Results from a 10-year experience.
Périodique
Epilepsia
Auteur⸱e⸱s
Bourdillon P., Isnard J., Catenoix H., Montavont A., Rheims S., Ryvlin P., Ostrowsky-Coste K., Mauguiere F., Guénot M.
ISSN
1528-1167 (Electronic)
ISSN-L
0013-9580
Statut éditorial
Publié
Date de publication
01/2017
Peer-reviewed
Oui
Volume
58
Numéro
1
Pages
85-93
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Stereo electroencephalography (SEEG)-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) has been proposed since 2004 as a possible treatment of some focal drug-resistant epilepsy. The aim of this study is to provide extensive data about efficacy and safety of SEEG-guided RF-TC.
Over a 10-year period, 162 patients with drug-resistant focal epilepsy were eligible for SEEG-guided RF-TG during phase II invasive investigation by SEEG. All follow-up and safety data were collected prospectively. The primary outcome was seizure freedom at 2 months and at 1 year after SEEG-guided RF-TC. Secondary outcomes were the responders' rate (patient with at least 50% decrease in seizure frequency) and their long-term follow-up.
Twenty-five percent of patients were seizure-free at 2 months and 7% at 1 year. We reported 67% of responders at 2 months and 48% at 1 year; 58% of responders maintained their status during the long-term follow-up. The seizure outcome was significantly better when the SEEG-guided RF-TC involved the occipital region (p = 0.007). When surgery followed an SEEG-guided RF-TC, the positive predictive value of being a responder 2 months after an SEEG-guided RF-TC and to be Engel's class I or II after surgery was 93%. We reported 1.1% of permanent deficit and 2.4% of transient side effects.
Our results, gathered in a large population over a 10-year period, confirm that SEEG-guided RF-TC is a safe technique, being efficient in many cases. More than two thirds of patients showed a short-term improvement, and almost half of them were responders at 1-year follow-up. The technique appears to be especially interesting for limited epileptic zone inaccessible to surgery and when epilepsy is related to a large unilateral network (network disruption by multiple RF-TC). Furthermore, SEEG-guided RF-TC effect is a predictor of outcome after conventional cortectomy in patients eligible for surgery.

Pubmed
Web of science
Open Access
Oui
Création de la notice
06/12/2016 18:33
Dernière modification de la notice
20/08/2019 17:11
Données d'usage