Effect of Conventional and Ultrahigh Dose Rate FLASH Irradiations on Preclinical Tumor Models: A Systematic Analysis.

Détails

Ressource 1Demande d'une copie Sous embargo indéterminé.
Accès restreint UNIL
Etat: Public
Version: Final published version
Licence: Non spécifiée
ID Serval
serval:BIB_E35A0EBD9890
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Effect of Conventional and Ultrahigh Dose Rate FLASH Irradiations on Preclinical Tumor Models: A Systematic Analysis.
Périodique
International journal of radiation oncology, biology, physics
Auteur⸱e⸱s
Böhlen T.T., Germond J.F., Petersson K., Ozsahin E.M., Herrera F.G., Bailat C., Bochud F., Bourhis J., Moeckli R., Adrian G.
ISSN
1879-355X (Electronic)
ISSN-L
0360-3016
Statut éditorial
Publié
Date de publication
15/11/2023
Peer-reviewed
Oui
Volume
117
Numéro
4
Pages
1007-1017
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Compared with conventional dose rate irradiation (CONV), ultrahigh dose rate irradiation (UHDR) has shown superior normal tissue sparing. However, a clinically relevant widening of the therapeutic window by UHDR, termed "FLASH effect," also depends on the tumor toxicity obtained by UHDR. Based on a combined analysis of published literature, the current study examined the hypothesis of tumor isoefficacy for UHDR versus CONV and aimed to identify potential knowledge gaps to inspire future in vivo studies.
A systematic literature search identified publications assessing in vivo tumor responses comparing UHDR and CONV. Qualitative and quantitative analyses were performed, including combined analyses of tumor growth and survival data.
We identified 66 data sets from 15 publications that compared UHDR and CONV for tumor efficacy. The median number of animals per group was 9 (range 3-15) and the median follow-up period was 30.5 days (range 11-230) after the first irradiation. Tumor growth assays were the predominant model used. Combined statistical analyses of tumor growth and survival data are consistent with UHDR isoefficacy compared with CONV. Only 1 study determined tumor-controlling dose (TCD <sub>50</sub> ) and reported statistically nonsignificant differences.
The combined quantitative analyses of tumor responses support the assumption of UHDR isoefficacy compared with CONV. However, the comparisons are primarily based on heterogeneous tumor growth assays with limited numbers of animals and short follow-up, and most studies do not assess long-term tumor control probability. Therefore, the assays may be insensitive in resolving smaller response differences, such as responses of radioresistant tumor subclones. Hence, tumor cure experiments, including additional TCD <sub>50</sub> experiments, are needed to confirm the assumption of isoeffectiveness in curative settings.
Mots-clé
Flash, tumour response, isoefficacy, meta-analysis, ultra-high dose rate, FLASH
Pubmed
Web of science
Open Access
Oui
Création de la notice
08/06/2023 14:43
Dernière modification de la notice
19/12/2023 8:13
Données d'usage