Detection of liver metastases from endocrine tumors: a prospective comparison of somatostatin receptor scintigraphy, computed tomography, and magnetic resonance imaging
Détails
ID Serval
serval:BIB_E22DA49F9CD8
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Detection of liver metastases from endocrine tumors: a prospective comparison of somatostatin receptor scintigraphy, computed tomography, and magnetic resonance imaging
Périodique
J Clin Oncol
ISSN-L
0732-183X (Print)0732-183X (Linking)
Statut éditorial
Publié
Date de publication
2005
Peer-reviewed
Oui
Volume
23
Numéro
1
Pages
70-8
Langue
anglais
Notes
Dromain, Clarissede Baere, ThierryLumbroso, JeanCaillet, HubertLaplanche, AgnesBoige, ValerieDucreux, MichelDuvillard, PierreElias, DominiqueSchlumberger, MartinSigal, RobertBaudin, EricengClinical TrialComparative StudyRandomized Controlled Trial2004/12/31 09:00J Clin Oncol. 2005 Jan 1;23(1):70-8.
Résumé
PURPOSE: To compare the respective sensitivity of somatostatin receptor scintigraphy (SRS), computed tomography (CT), and magnetic resonance imaging (MRI) in the detection of liver metastases from well-differentiated gastroenteropancreatic endocrine tumor (WDGEP ET) patients. To define predictive factors for "high-sensitivity SRS." PATIENTS AND METHODS: Sixty-four patients with WDGEP ET underwent SRS with abdominal single-photon emission computed tomography (SPECT), spiral CT, and 1.5-T MRI within a 15-day interval, the order of which was randomized. Two readers analyzed images of each modality, blindly and independently. RESULTS: Hepatic metastases were present in 40 of the 64 patients and confirmed by pathology after liver biopsy or surgery in 32 and eight patients, respectively. SRS, CT, and MRI detected a total of 204, 325, and 394 metastases, respectively. The number of detected metastases was significantly higher with MRI than with CT (P = .02) and SRS (P < 10(-4)) and higher with CT than with SRS (P < 10(-4)). SRS was negative in seven patients with a positive CT and/or MRI. More lesions were detected in 10 patients by SPECT compared with static views. The median metastasis size was significantly correlated (P = .04) with the sensitivity of SRS. CONCLUSION: MRI seems to have an edge over CT and SRS for the detection of liver metastases from endocrine tumors. We recommend the systematic performance of liver MRI at WDGEP ET initial staging and before major therapeutic events. The low performance of SRS was mainly explained by the impact of the metastasis size on the detection capacity of SRS.
Mots-clé
Adolescent, Adult, Aged, Endocrine Gland Neoplasms/*pathology, Female, Humans, Liver Neoplasms/*diagnosis/*secondary, *Magnetic Resonance Imaging, Male, Middle Aged, Prospective Studies, Receptors, Somatostatin/analysis, *Tomography, Emission-Computed, Single-Photon, *Tomography, X-Ray Computed
Site de l'éditeur
Création de la notice
16/09/2016 10:14
Dernière modification de la notice
20/08/2019 16:06