Dosimetria in vivo e verifica radiografica nella radioterapia del linfoma di Hodgkin. [In vivo dosimetry and radiographic confirmation in radiotherapy of Hodgkin's lymphoma]
Détails
ID Serval
serval:BIB_DE8C2E5F0B1E
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Dosimetria in vivo e verifica radiografica nella radioterapia del linfoma di Hodgkin. [In vivo dosimetry and radiographic confirmation in radiotherapy of Hodgkin's lymphoma]
Périodique
Radiologia Medica
ISSN
0033-8362 (Print)
Statut éditorial
Publié
Date de publication
03/1994
Volume
87
Numéro
3
Pages
312-8
Notes
English Abstract Journal Article --- Old month value: Mar
Résumé
In September 1991 a protocol for quality control of large shaped irradiation fields was started in our department. In vivo dosimetry with semiconductor detectors was used to measure the absorbed dose and patient positioning was checked with portal films weekly. First, we set a computed dosimetric system yielding dosimetric values in real time and allowing their easy storage. Then, we calibrated the diodes and determined the correction factors for each of them outside standard conditions. Entrance dose, exit dose and midline dose were measured in 62 patients undergoing supradiaphragmatic radiation therapy for Hodgkin's lymphoma. The exist dose was measured weekly to assess treatment repeatability. High agreement was observed between measured and calculated doses; repeatability was also high, since only 6% of exit dose measurements exceeded 5% of the first determination. In 33 patients portal films were obtained in the first treatment session, and thereafter weekly, to assess mispositioning relative to simulation (reproducibility) and from one session to another (repeatability). A small systematic error was detected in both longitudinal (x = -3 mm; SD = 3.7 mm) and transverse (x = -2 mm; SD = 3.4 mm) directions. Statistically significant errors (> 6 mm) were observed in 14% of patients. Reproducibility was excellent. The protocol reported on in this paper not only helps avoid systematic dosimetric and/or positioning errors in the patients, but also helps identify the main causes of uncertainty and thus remove them.
Mots-clé
Hodgkin Disease/*radiography/*radiotherapy Humans Radiotherapy Dosage *Radiotherapy Planning, Computer-Assisted Reproducibility of Results
Pubmed
Création de la notice
24/01/2008 17:18
Dernière modification de la notice
20/08/2019 16:03