Computed Tomography Angiography for the Diagnosis of Coronary Artery Disease Among Patients Undergoing Transcatheter Aortic Valve Implantation.

Détails

Ressource 1Demande d'une copie Sous embargo indéterminé.
Accès restreint UNIL
Etat: Public
Version: de l'auteur⸱e
Licence: CC BY 4.0
ID Serval
serval:BIB_DC7865DBAB0F
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Computed Tomography Angiography for the Diagnosis of Coronary Artery Disease Among Patients Undergoing Transcatheter Aortic Valve Implantation.
Périodique
Journal of cardiovascular translational research
Auteur⸱e⸱s
Meier D., Depierre A., Topolsky A., Roguelov C., Dupré M., Rubimbura V., Eeckhout E., Qanadli S.D., Muller O., Mahendiran T., Rotzinger D., Fournier S.
ISSN
1937-5395 (Electronic)
ISSN-L
1937-5387
Statut éditorial
Publié
Date de publication
10/2021
Peer-reviewed
Oui
Volume
14
Numéro
5
Pages
894-901
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
Computed tomography angiography (CTA) is used to plan TAVI procedures. We investigated the performance of pre-TAVI CTA for excluding coronary artery disease (CAD).
In total 127 patients were included. CTA images were analyzed for the presence of ≥ 50% (significant CAD) and ≥ 70% (severe CAD) diameter stenoses in proximal coronary arteries. Results were compared with invasive coronary angiography (ICA) at vessel and patient levels. Primary endpoint was the negative predictive value (NPV) of CTA for the presence of CAD.
A total of 342 vessels were analyzable. NPV of CTA was 97.5% for significant CAD and 96.3% for severe CAD. Positive predictive value and accuracy were 44.8% and 87.1% for significant CAD and 56.3% and 94.4% for severe CAD. At patient level, NPV for significant CAD was 88.6%.
Pre-TAVI CTA shows good performance for ruling out CAD and could be used as a gatekeeper for ICA in selected patients.
Mots-clé
Aortic valve stenosis, Computed tomography angiography, Coronary artery disease, Transcatheter aortic valve implantation