Improved Surgical Technique Reduces Complications at the Gastro-jejunostomy After Laparoscopic Roux-en-Y Gastric Bypass

Détails

ID Serval
serval:BIB_D92DB8E7AB7D
Type
Actes de conférence (partie): contribution originale à la littérature scientifique, publiée à l'occasion de conférences scientifiques, dans un ouvrage de compte-rendu (proceedings), ou dans l'édition spéciale d'un journal reconnu (conference proceedings).
Sous-type
Abstract (résumé de présentation): article court qui reprend les éléments essentiels présentés à l'occasion d'une conférence scientifique dans un poster ou lors d'une intervention orale.
Collection
Publications
Institution
Titre
Improved Surgical Technique Reduces Complications at the Gastro-jejunostomy After Laparoscopic Roux-en-Y Gastric Bypass
Titre de la conférence
4th IFSO-European Chapter Congress
Auteur⸱e⸱s
Suter M., Donadini A., Calmes J.M., Romy S.
Adresse
Lausanne, Switzerland, April 22nd-24th, 2010
ISBN
0960-8923
Statut éditorial
Publié
Date de publication
2010
Peer-reviewed
Oui
Volume
20
Série
Obesity Surgery
Pages
816
Langue
anglais
Notes
Meeting Abstract
Résumé
Introduction:
Roux-en-Y gastric bypass (RYGBP) is one of the commonest procedure for morbid obesity. It is associated with effective long-term weight loss, but can lead to significant complications, especially at the gastrojejunostomy (GJS)
Patients and Methods:
All the patients undergoing laparoscopic RYGBP at one of our two institutions were included in this study, in which we compared two different techniques for the construction of the GJS and their effects on the incidence of complications. In group A, anatomosis was performed on the posterior aspect of the gastric pouch. In group B it was performed across the staple line used to form the gastric pouch. A 21-mm circular stapler was used in all patients.
Results:
A total of 1128 patients were included between June 1999 and September 2009, 639 in group A and 488 in group B. Sixty patients developed a total of 65 complications at the GJS, with 14 (1,2 %) leaks, 42 (3,7 %) stricture, and 9 (0,8 %) marginal ulcers. Leaks (0,2 versus 2 %, p=0,005) and strictures (0,8 versus 5,9%, p<0,0001) were significantly fewer in group B than in group A.
Conclusions:
Improved surgical technique, with the GJS across the staple line used to form the gastric pouch, significantly reduces the rate of anastomotic complications at the GJS. A circular 21-mm stapler can be used with a low complication rate, and especially a low stricture rate. Additional methods to limit complications at the GJS are probably not routinely warranted.
Web of science
Création de la notice
23/06/2010 13:19
Dernière modification de la notice
20/08/2019 16:58
Données d'usage