Salvage treatment for venous aneurysm complicating vascular access arteriovenous fistula: use of an exoprosthesis to reinforce the vein after aneurysmorrhaphy.

Détails

ID Serval
serval:BIB_D40D9F71F43C
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Salvage treatment for venous aneurysm complicating vascular access arteriovenous fistula: use of an exoprosthesis to reinforce the vein after aneurysmorrhaphy.
Périodique
European Journal of Vascular and Endovascular Surgery
Auteur⸱e⸱s
Berard X., Brizzi V., Mayeux S., Sassoust G., Biscay D., Ducasse E., Bordenave L., Corpataux J.M., Midy D.
ISSN
1532-2165[electronic], 1078-5884[linking]
Statut éditorial
Publié
Date de publication
2010
Volume
40
Numéro
1
Pages
100-106
Langue
anglais
Résumé
OBJECTIVES: We report a new salvage technique for treating venous aneurysms (VAs) complicating vascular access arteriovenous fistula (AVF) using externally reinforced venous aneurysmorrhaphy.
DESIGN: A retrospective study over a 20-month period from a single centre.
PATIENTS: Patients presenting to the vascular surgery department, Bordeaux University Hospital for revision of a vascular access AVF were included.
METHODS: Reinforced venous aneurysmorrhaphy consisted in removal of redundant vessel wall followed by reinforcement using an external prosthetic graft. Patency, diameter and flow were assessed by duplex ultrasound at 1, 6 and 12 months after salvage.
RESULTS: Thirty-eight eligible patients were identified. Five were excluded because VA was associated with central vein stenosis; the remaining 33 underwent salvage. Indications were rapidly expanding or painful VA in seven cases; VA with frequent bleeding or damaged overlying skin in eight; VA in close relation to a stenosis in two; and VA associated with high-flow rate in 16. Cannulation was attempted after 30 days. Mean follow-up time was 12 S.D. 5 months (range: 4-22). Two repaired AVFs failed. Primary 1-year patency was 93%. No aneurysm or infection occurred. Reduction of high flow was successful in 12 of 16 patients. The remaining four required re-operation.
CONCLUSIONS: Reinforced venous aneurysmorrhaphy is effective in controlling venous dilation and achieving patency. Reduction of high-flow rates was not always achieved. Further study is needed to evaluate long-term efficacy of this treatment.
Mots-clé
Adolescent, Adult, Aged, Aged, 80 and over, Aneurysm/etiology, Aneurysm/physiopathology, Arteriovenous Shunt, Surgical/adverse effects, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation/adverse effects, Blood Vessel Prosthesis Implantation/instrumentation, Female, France, Humans, Kaplan-Meiers Estimate, Male, Middle Aged, Prosthesis Design, Regional Blood Flow, Renal Dialysis, Reoperation, Retrospective Studies, Salvage Therapy, Time Factors, Treatment Outcome, Ultrasonography, Doppler, Duplex, Upper Extremity/blood supply, Vascular Patency, Veins/surgery, Young Adult
Pubmed
Web of science
Open Access
Oui
Création de la notice
02/09/2010 11:39
Dernière modification de la notice
20/08/2019 15:54
Données d'usage