Time since discharge of 9mm cartridges by headspace analysis, part 1: Comprehensive optimisation and validation of a headspace sorptive extraction (HSSE) method.

Détails

Ressource 1Télécharger: Gallidabino et al. Time since discharge of 9mm using HSSE - PART I (in press).pdf (1280.38 [Ko])
Etat: Public
Version: Author's accepted manuscript
ID Serval
serval:BIB_D3B434F048CA
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Time since discharge of 9mm cartridges by headspace analysis, part 1: Comprehensive optimisation and validation of a headspace sorptive extraction (HSSE) method.
Périodique
Forensic science international
Auteur⸱e⸱s
Gallidabino M., Romolo F.S., Weyermann C.
ISSN
1872-6283 (Electronic)
ISSN-L
0379-0738
Statut éditorial
Publié
Date de publication
03/2017
Peer-reviewed
Oui
Volume
272
Pages
159-170
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Estimating the time since discharge of spent cartridges can be a valuable tool in the forensic investigation of firearm-related crimes. To reach this aim, it was previously proposed that the decrease of volatile organic compounds released during discharge is monitored over time using non-destructive headspace extraction techniques. While promising results were obtained for large-calibre cartridges (e.g., shotgun shells), handgun calibres yielded unsatisfying results. In addition to the natural complexity of the specimen itself, these can also be attributed to some selective choices in the methods development. Thus, the present series of paper aimed to more systematically evaluate the potential of headspace analysis to estimate the time since discharge of cartridges through the use of more comprehensive analytical and interpretative techniques. Specifically, in this first part, a method based on headspace sorptive extraction (HSSE) was comprehensively optimised and validated, as the latter recently proved to be a more efficient alternative than previous approaches. For this purpose, 29 volatile organic compounds were preliminary selected on the basis of previous works. A multivariate statistical approach based on design of experiments (DOE) was used to optimise variables potentially involved in interaction effects. Introduction of deuterated analogues in sampling vials was also investigated as strategy to account for analytical variations. Analysis was carried out by selected ion mode, gas chromatography coupled to mass spectrometry (GC-MS). Results showed good chromatographic resolution as well as detection limits and peak area repeatability. Application to 9mm spent cartridges confirmed that the use of co-extracted internal standards allowed for improved reproducibility of the measured signals. The validated method will be applied in the second part of this work to estimate the time since discharge of 9mm spent cartridges using multivariate models.

Mots-clé
forensic science, firearm, gunshot residue, sorptive extraction, design of experiments, time since discharge, Design of experiments, Firearm, Forensic science, Gunshot residue, Sorptive extraction, Time since discharge
Pubmed
Web of science
Open Access
Oui
Création de la notice
03/09/2015 15:01
Dernière modification de la notice
20/08/2019 16:53
Données d'usage