Standardizing Flow Cytometry Immunophenotyping Analysis from the Human ImmunoPhenotyping Consortium.
Détails
ID Serval
serval:BIB_CB77E8F95B49
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Standardizing Flow Cytometry Immunophenotyping Analysis from the Human ImmunoPhenotyping Consortium.
Périodique
Scientific reports
ISSN
2045-2322 (Electronic)
ISSN-L
2045-2322
Statut éditorial
Publié
Date de publication
10/02/2016
Peer-reviewed
Oui
Volume
6
Pages
20686
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, N.I.H., Extramural ; Research Support, N.I.H., Intramural ; Research Support, Non-U.S. Gov't
Publication Status: epublish
Publication Status: epublish
Résumé
Standardization of immunophenotyping requires careful attention to reagents, sample handling, instrument setup, and data analysis, and is essential for successful cross-study and cross-center comparison of data. Experts developed five standardized, eight-color panels for identification of major immune cell subsets in peripheral blood. These were produced as pre-configured, lyophilized, reagents in 96-well plates. We present the results of a coordinated analysis of samples across nine laboratories using these panels with standardized operating procedures (SOPs). Manual gating was performed by each site and by a central site. Automated gating algorithms were developed and tested by the FlowCAP consortium. Centralized manual gating can reduce cross-center variability, and we sought to determine whether automated methods could streamline and standardize the analysis. Within-site variability was low in all experiments, but cross-site variability was lower when central analysis was performed in comparison with site-specific analysis. It was also lower for clearly defined cell subsets than those based on dim markers and for rare populations. Automated gating was able to match the performance of central manual analysis for all tested panels, exhibiting little to no bias and comparable variability. Standardized staining, data collection, and automated gating can increase power, reduce variability, and streamline analysis for immunophenotyping.
Mots-clé
Algorithms, Automation, B-Lymphocytes/cytology, B-Lymphocytes/immunology, B-Lymphocytes/metabolism, Flow Cytometry/methods, Flow Cytometry/standards, Humans, Immunophenotyping/methods, Immunophenotyping/standards, Laboratories/standards, Leukocytes, Mononuclear/cytology, Leukocytes, Mononuclear/immunology, Leukocytes, Mononuclear/metabolism, T-Lymphocytes/cytology, T-Lymphocytes/immunology, T-Lymphocytes/metabolism