Swiss survey on hybrid imaging CTs doses in Nuclear Medicine and proposed national dose reference levels.

Détails

ID Serval
serval:BIB_C712E05C9E9C
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Swiss survey on hybrid imaging CTs doses in Nuclear Medicine and proposed national dose reference levels.
Périodique
Zeitschrift fur medizinische Physik
Auteur⸱e⸱s
Lima TVM, Gnesin S., Ryckx N., Strobel K., Stritt N., Linder R.
Collaborateur⸱rice⸱s
Swiss Workgroup on Nuclear Medicine DRLs
ISSN
1876-4436 (Electronic)
ISSN-L
0939-3889
Statut éditorial
Publié
Date de publication
12/2018
Peer-reviewed
Oui
Volume
28
Numéro
4
Pages
265-275
Langue
anglais
Notes
Publication types: Journal Article ; Review
Publication Status: ppublish
Résumé
A multidisciplinary working group led by the Swiss Federal Office of Public Health was formed to plan and perform a nationwide survey of patient radiation exposure from computed tomography (CT) in hybrid devices across Nuclear Medicine departments. The survey included 16 departments (of which 5 were university hospitals) and the submitted responses included 10,673 entries for the 33 different protocols proposed (11 in PET and 22 in SPECT). The working group determined the selection and exclusion criteria applied to the analysis. This work presents the survey preparation and data analysis including the exclusion criteria used. The results are used to inform recommendations for National Diagnostic Reference Levels (DRL) for CT procedures in Nuclear Medicine in Switzerland. Of the 33 protocols initially proposed, 10 protocols for both PET and SPECT modalities were retained after exclusion criteria and thresholds were applied. The results obtained in terms of volume-weighted computed tomography dose index (CTDI <sub>vol</sub> ) and dose length product (DLP) have been put forward as recommendations for national Diagnostic Reference Levels for protocols in hybrid imaging devices in Nuclear Medicine in Switzerland and will be published by the Federal Office of Public Health.
Mots-clé
Humans, Multimodal Imaging/statistics & numerical data, Nuclear Medicine/statistics & numerical data, Radiation Dosage, Radiation Exposure/statistics & numerical data, Reference Values, Surveys and Questionnaires, Switzerland, Tomography, X-Ray Computed/statistics & numerical data, CT doses, DRL, Hybrid devices, National survey, Nuclear Medicine, Patient exposure
Pubmed
Web of science
Création de la notice
01/03/2018 19:31
Dernière modification de la notice
20/08/2019 16:42
Données d'usage