4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.

Détails

ID Serval
serval:BIB_C6FC36C68F88
Type
Article: article d'un périodique ou d'un magazine.
Sous-type
Synthèse (review): revue aussi complète que possible des connaissances sur un sujet, rédigée à partir de l'analyse exhaustive des travaux publiés.
Collection
Publications
Institution
Titre
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.
Périodique
Journal of cardiovascular magnetic resonance
Auteur⸱e⸱s
Bissell M.M., Raimondi F., Ait Ali L., Allen B.D., Barker A.J., Bolger A., Burris N., Carhäll C.J., Collins J.D., Ebbers T., Francois C.J., Frydrychowicz A., Garg P., Geiger J., Ha H., Hennemuth A., Hope M.D., Hsiao A., Johnson K., Kozerke S., Ma L.E., Markl M., Martins D., Messina M., Oechtering T.H., van Ooij P., Rigsby C., Rodriguez-Palomares J., Roest AAW, Roldán-Alzate A., Schnell S., Sotelo J., Stuber M., Syed A.B., Töger J., van der Geest R., Westenberg J., Zhong L., Zhong Y., Wieben O., Dyverfeldt P.
ISSN
1532-429X (Electronic)
ISSN-L
1097-6647
Statut éditorial
Publié
Date de publication
20/07/2023
Peer-reviewed
Oui
Volume
25
Numéro
1
Pages
40
Langue
anglais
Notes
Publication types: Journal Article ; Review ; Research Support, N.I.H., Extramural ; Research Support, Non-U.S. Gov't
Publication Status: epublish
Résumé
Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.
Mots-clé
Humans, Blood Flow Velocity, Predictive Value of Tests, Cardiovascular System, Heart, Magnetic Resonance Imaging, Magnetic Resonance Spectroscopy, 4D Flow CMR, 4D Flow MRI, Cardiovascular, Clinical, Flow quantification, Flow visualization, Heart disease, Hemodynamics, MR flow imaging, Phase-contrast magnetic resonance imaging, Recommendations