Design and establishment of a biobank in a multicenter prospective cohort study of elderly patients with venous thromboembolism (SWITCO65+).

Détails

ID Serval
serval:BIB_C609524CD3E8
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Design and establishment of a biobank in a multicenter prospective cohort study of elderly patients with venous thromboembolism (SWITCO65+).
Périodique
Journal of Thrombosis and Thrombolysis
Auteur⸱e⸱s
Méan M., Aujesky D., Lämmle B., Gerschheimer C., Trelle S., Angelillo-Scherrer A.
ISSN
1573-742X (Electronic)
ISSN-L
0929-5305
Statut éditorial
Publié
Date de publication
2013
Peer-reviewed
Oui
Volume
36
Numéro
4
Pages
484-491
Langue
anglais
Notes
Publication types: Journal Article Publication Status: ppublish
Résumé
In the field of thrombosis and haemostasis, many preanalytical variables influence the results of coagulation assays and measures to limit potential results variations should be taken. To our knowledge, no paper describing the development and maintenance of a haemostasis biobank has been previously published. Our description of the biobank of the Swiss cohort of elderly patients with venous thromboembolism (SWITCO65+) is intended to facilitate the set-up of other biobanks in the field of thrombosis and haemostasis. SWITCO65+ is a multicentre cohort that prospectively enrolled consecutive patients aged ≥65 years with venous thromboembolism at nine Swiss hospitals from 09/2009 to 03/2012. Patients will be followed up until December 2013. The cohort includes a biobank with biological material from each participant taken at baseline and after 12 months of follow-up. Whole blood from all participants is assayed with a standard haematology panel, for which fresh samples are required. Two buffy coat vials, one PAXgene Blood RNA System tube and one EDTA-whole blood sample are also collected at baseline for RNA/DNA extraction. Blood samples are processed and vialed within 1 h of collection and transported in batches to a central laboratory where they are stored in ultra-low temperature archives. All analyses of the same type are performed in the same laboratory in batches. Using multiple core laboratories increased the speed of sample analyses and reduced storage time. After recruiting, processing and analyzing the blood of more than 1,000 patients, we determined that the adopted methods and technologies were fit-for-purpose and robust.
Pubmed
Web of science
Création de la notice
07/12/2013 17:41
Dernière modification de la notice
21/10/2019 21:49
Données d'usage