Measurement of infarct size in acute canine myocardial infarction by single-photon emission computed tomography with technetium-99m pyrophosphate

Détails

ID Serval
serval:BIB_BD8563C3AFFD
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Measurement of infarct size in acute canine myocardial infarction by single-photon emission computed tomography with technetium-99m pyrophosphate
Périodique
American Journal of Cardiology
Auteur⸱e⸱s
Lewis  S. E., Devous, M. D., Sr. , Corbett  J. R., Izquierdo  C., Nicod  P., Wolfe  C. L., Parkey  R. W., Buja  L. M., Willerson  J. T.
ISSN
0002-9149 (Print)
Statut éditorial
Publié
Date de publication
07/1984
Volume
54
Numéro
1
Pages
193-9
Notes
Journal Article
Research Support, Non-U.S. Gov't
Research Support, U.S. Gov't, P.H.S. --- Old month value: Jul 1
Résumé
The location and extent of myocardial infarction (MI) are important predictors of patient course. The current study tests the hypothesis that MI size could be measured accurately using rotating gamma camera single-photon emission computed tomography ( SPECT ) and technetium-99m pyrophosphate (PPi) and that the accuracy of these measurements was independent of MI location and transmural or nontransmural distribution. SPECT was performed in 38 dogs 48 hours after ligation of the left anterior descending coronary artery (14 dogs) or left circumflex coronary artery (LC) (24 dogs) at the mid-level or below. Projection images were corrected for center-of-rotation and field nonuniformity and processed with a 1-dimensional low-pass filter to diminish rib activity. Sixteen 0.5-cm-thick transverse sections, including the entire left ventricle, were reconstructed by filtered backprojection , low-pass filtered, contrast enhanced and processed with a 3-dimensional boundary enhancement operator. The boundary of PPi uptake in each slice was marked automatically using an algorithm that combined a directional derivative and a threshold, and required continuity of the boundary in 3 dimensions. The total number of volume elements that showed abnormal tracer uptake were summed, corrected to absolute volume, and multiplied by the specific weight of cardiac muscle. Scintigraphic MI weight was compared with pathologic MI weight. There was an excellent correlation between scintigraphic and pathologic MI weight. The poorer correlation for nontransmural compared with transmural MIs is most likely a function of size alone, since MIs that weighed less than 10 g (n = 12, range 1.3 to 9.5 g), both transmural and nontransmural, showed a similar correlation: S = 1.07 X P + 0.56 (r = 0.81, standard error of the slope = 0.245).(ABSTRACT TRUNCATED AT 250 WORDS)
Mots-clé
Animals Coronary Vessels/pathology Diphosphates/*diagnostic use Dogs Ligation Myocardial Infarction/pathology/*radionuclide imaging Technetium/*diagnostic use Technetium Tc 99m Pyrophosphate *Tomography, Emission-Computed
Pubmed
Web of science
Création de la notice
25/01/2008 15:00
Dernière modification de la notice
20/08/2019 16:31
Données d'usage