Objective assessment of image quality in conventional and digital mammography taking into account dynamic range.

Détails

Ressource 1Télécharger: REF.pdf (60.67 [Ko])
Etat: Public
Version: Final published version
Licence: Non spécifiée
It was possible to publish this article open access thanks to a Swiss National Licence with the publisher.
ID Serval
serval:BIB_B9E297BAB92B
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Objective assessment of image quality in conventional and digital mammography taking into account dynamic range.
Périodique
Radiation protection dosimetry
Auteur⸱e⸱s
Pachoud M., Lepori D., Valley J.F., Verdun F.R.
ISSN
0144-8420
Statut éditorial
Publié
Date de publication
2005
Peer-reviewed
Oui
Volume
114
Numéro
1-3
Pages
380-2
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't - Publication Status: ppublish
Résumé
The goal of this work is to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality. The method takes into account the dynamic range of the image detector, the detection of high and low contrast structures, the visualisation of the images and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualisation process in the image quality assessment. A mathematical model observer (non-prewhitening matched filter), that calculates the detectability of high and low contrast structures using spatial resolution, noise and contrast, was used to compare the two technologies. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. The method of using a test object with a large tissue composition range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimise the process of radiographic reading of soft copy images.
Mots-clé
Breast, Breast Diseases, Breast Neoplasms, Humans, Image Processing, Computer-Assisted, Mammography, Phantoms, Imaging, Quality Control, Radiation Dosage, Radiographic Image Enhancement, Radiographic Image Interpretation, Computer-Assisted, Radiographic Magnification, Radiography, Radiology, Radiometry, X-Ray Intensifying Screens
Pubmed
Web of science
Open Access
Oui
Création de la notice
29/02/2008 18:45
Dernière modification de la notice
14/02/2022 8:56
Données d'usage