Persistent root abscess after emergency repair with an aortic homograft
Détails
ID Serval
serval:BIB_B99284A53884
Type
Article: article d'un périodique ou d'un magazine.
Sous-type
Etude de cas (case report): rapporte une observation et la commente brièvement.
Collection
Publications
Institution
Titre
Persistent root abscess after emergency repair with an aortic homograft
Périodique
British Heart Journal
ISSN
0007-0769
Statut éditorial
Publié
Date de publication
11/1994
Peer-reviewed
Oui
Volume
72
Numéro
5
Pages
495-7
Notes
Case Reports
Journal Article --- Old month value: Nov
Journal Article --- Old month value: Nov
Résumé
A fifty eight year old man with Marfan's syndrome and an aortic composite graft with a Bjork-Shiley mechanical prosthesis presented with a large aortic root abscess caused by Staphylococcus aureus endocarditis. Despite extensive surgical debridement and implantation of an aortic homograft as a composite graft, early postoperative transoesophageal echocardiography continued to demonstrate a large aortic root abscess and the patient died in a septic shock.
Mots-clé
Abscess/*complications/microbiology/pathology
Aorta/transplantation
*Aortic Valve
Endocarditis, Bacterial/*complications/pathology/surgery
Heart Valve Diseases/*complications/microbiology/pathology/surgery
*Heart Valve Prosthesis
Humans
Male
Middle Aged
Pericardium/transplantation
Staphylococcal Infections/*complications/pathology/surgery
*Staphylococcus aureus
Pubmed