Active personal dosemeters in interventional radiology: tests in laboratory conditions and in hospitals
Périodique
Radiation Protection Dosimetry
Auteur⸱e⸱s
Clairand I., Bordy J.M., Daures J., Debroas J., Denozière M., Donadille L., Ginjaume M., Itié C., Koukorava C., Krim S., Lebacq A.L., Martin P., Struelens L., Sans-Mercé M., Tosic M., Vanhavere F.
ISSN
1742-3406 (Electronic)
ISSN-L
0144-8420
Statut éditorial
Publié
Date de publication
2010
Volume
144
Numéro
1-4
Pages
453-458
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Résumé
The work package 3 of the ORAMED project, Collaborative Project (2008-11) supported by the European Commission within its seventh Framework Programme, is focused on the optimisation of the use of active personal dosemeters (APDs) in interventional radiology and cardiology (IR/IC). Indeed, a lack of appropriate APD devices is identified for these specific fields. Few devices can detect low-energy X rays (20-100 keV), and none of them are specifically designed for working in pulsed radiation fields. The work presented in this paper consists in studying the behaviour of some selected APDs deemed suitable for application in IR/IC. For this purpose, measurements under laboratory conditions, both with continuous and pulsed X-ray beams, and tests in real conditions on site in different European hospitals were performed. This study highlights the limitations of APDs for this application and the need of improving the APD technology so as to fulfil all needs in the IR/IC field.
Mots-clé
Cardiology/manpower, Occupational Exposure/prevention & control, Radiation Monitoring/instrumentation, Radiation Monitoring/methods, Radiation Protection/instrumentation, Radiation Protection/methods, Radiology, Interventional/manpower, Radiometry/instrumentation, Radiometry/methods