Impact of Full Spectrum Endoscopy® (Fuse®, EndoChoice®) on adenoma detection: a prospective French pilot study.

Détails

ID Serval
serval:BIB_B54492BAF500
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
Impact of Full Spectrum Endoscopy® (Fuse®, EndoChoice®) on adenoma detection: a prospective French pilot study.
Périodique
Annals of gastroenterology
Auteur⸱e⸱s
Ratone J.P., Bories E., Caillol F., Pesenti C., Godat S., Sellier F., Hoibian S., Landon M., Servajean C., Cassan C., Lestelle V., Casanova J.P., Poizat F., Giovannini M.
ISSN
1108-7471 (Print)
ISSN-L
1108-7471
Statut éditorial
Publié
Date de publication
2017
Peer-reviewed
Oui
Volume
30
Numéro
5
Pages
512-517
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: ppublish
Résumé
Currently, colonoscopy and polypectomy are the gold standard methods for the prevention of incident cases of colorectal cancer. The use of a new colonoscope (Fuse <sup>®</sup> , EndoChoice <sup>®</sup> ) with a larger view of up to 330° appears to improve the adenoma detection rate (ADR). We performed a prospective observational study concerning this scope. The primary endpoint was potentially omitted adenomas (POA), i.e. adenomas seen on the side screens that will not appear on the central display during colonoscopy withdrawal without oriented movements. Secondary endpoints included our ADR, Fuse <sup>®</sup> impact on ADR, time to cecal intubation and withdrawal time.
We performed a single-center prospective study in one French center. We enrolled patients over 18 years of age between January 2015 and March 2016.
We included 141 patients; 3 were excluded because their colonoscopies were incomplete. Our study included 78 men and 60 women (sex ratio 1.3). The mean age was 60.4 years. A total of 130 polyps were resected. In all, 88/130 were adenomas (68%) and 34/88 adenomas (39%) were POA. The mean time to cecum was 10 min, and the mean withdrawal time was 12 min. ADR was 35% for men and 31% for women. The estimated ADR without POA was 29% for men and 19% for women.
The Fuse <sup>®</sup> system appears to be safe and efficient. POA represented 39% of all adenomas. The impact of the panoramic view on the ADR was considered substantial. The main limitations are the lack of randomization and the absence of a control group.
Mots-clé
Keywords Panoramic view, adenoma detection rate, missed adenomas
Pubmed
Web of science
Open Access
Oui
Création de la notice
07/10/2019 15:31
Dernière modification de la notice
01/11/2019 7:26
Données d'usage