Comparison of different software for processing physical activity measurements with accelerometry.
Détails
Télécharger: 41598_2023_Article_29872.pdf (1065.92 [Ko])
Etat: Public
Version: Final published version
Licence: CC BY 4.0
Etat: Public
Version: Final published version
Licence: CC BY 4.0
ID Serval
serval:BIB_B1387961EAD3
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Comparison of different software for processing physical activity measurements with accelerometry.
Périodique
Scientific reports
ISSN
2045-2322 (Electronic)
ISSN-L
2045-2322
Statut éditorial
Publié
Date de publication
18/02/2023
Peer-reviewed
Oui
Volume
13
Numéro
1
Pages
2879
Langue
anglais
Notes
Publication types: Journal Article
Publication Status: epublish
Publication Status: epublish
Résumé
Several raw-data processing software for accelerometer-measured physical activity (PA) exist, but whether results agree has not been assessed. We examined the agreement between three different software for raw accelerometer data, and associated their results with cardiovascular risk. A cross-sectional analysis conducted between 2014 and 2017 in 2693 adults (53.4% female, 45-86 years) living in Lausanne, Switzerland was used. Participants wore the wrist-worn GENEActive accelerometer for 14 days. Data was processed with the GENEActiv manufacturer software, the Pampro package in Python and the GGIR package in R. For the latter, two sets of thresholds "White" and "MRC" defining levels of PA and two versions (1.5-9 and 1.11-1) for the "MRC" threshold were used. Cardiovascular risk was assessed using the SCORE risk score. Time spent (mins/day) in stationary, light, moderate and vigorous PA ranged from 633 (GGIR-MRC) to 1147 (Pampro); 93 (GGIR-White) to 196 (GGIR-MRC); 19 (GGIR-White) to 161 (GENEActiv) and 1 (GENEActiv) to 26 (Pampro), respectively. Spearman correlations between results ranged between 0.317 and 0.995, while concordance coefficients ranged between 0.035 and 0.968. With some exceptions, the line of perfect agreement was not in the 95% confidence interval of the Bland-Altman plots. Compliance to PA guidelines varied considerably: 99.8%, 98.7%, 76.3%, 72.6% and 50.2% for Pampro, GENEActiv, GGIR-MRC v.1.11-1, GGIR-MRC v.1.4-9 and GGIR-White, respectively. Cardiovascular risk decreased with increasing time spent in PA across most software packages. We found large differences in PA estimation between software and thresholds used, which makes comparability between studies challenging.
Mots-clé
Adult, Humans, Female, Male, Cross-Sectional Studies, Accelerometry, Exercise, Heart Disease Risk Factors, Software
Pubmed
Web of science
Open Access
Oui
Création de la notice
03/03/2023 14:08
Dernière modification de la notice