Prevention of residual ventricular septal defects with fibrin sealant

Détails

ID Serval
serval:BIB_B097C1646657
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Prevention of residual ventricular septal defects with fibrin sealant
Périodique
Annals of Thoracic Surgery
Auteur⸱e⸱s
von Segesser  L. K., Fasnacht  M. S., Vogt  P. R., Genoni  M., Arbenz  U., Turina  M. I.
ISSN
0003-4975
Statut éditorial
Publié
Date de publication
09/1995
Peer-reviewed
Oui
Volume
60
Numéro
3
Pages
511-516
Notes
Clinical Trial Controlled Clinical Trial Journal Article --- Old month value: Sep
Résumé
BACKGROUND. Modern echocardiography now allows for the detection of a substantial number of residual ventricular septal defects (VSDs) after surgical patch repair that remained hidden in the past. Mostly without hemodynamic significance, residual VSDs may have clinical consequences (progressive dehiscence, hemolysis, prophylactic antibiotic treatment, endocarditis). To reduce the number and size of residual VSDs we performed an experimental and a clinical study. METHODS. (1) In an experimental setup, burst pressure of 60 fibrin glue-sealed defects (calibrated between 1.0 and 5.0 mm in diameter) was determined using a computerized recording system and pressure loads up to 500 mm Hg. (2) In a prospective clinical trial with blinded postoperative echocardiographic controls VSD closure was performed in 36 consecutive patients (age, 37 +/- 40 months; range, 4 to 134 months) using a polytetrafluoroethylene patch and running sutures reinforced with pledgets (22 of 36 patients) or sealed with fibrin glue (14 of 36 patients) in accordance to the surgeon's preference. RESULTS. (1) Experimentally, mean pressure load achieved was more than 500 +/- 0 mm Hg for 1.0-mm defects, 413 +/- 52 mm Hg for 2.5-mm defects, 363 +/- 58 mm Hg for 4.0-mm defects, and 313 +/- 48 mm Hg for 5.0-mm defects (r 0.873, p < 0.001). (2) Clinically, all patients survived. Residual VSDs at echocardiography were observed in 16 of 22 patients (72%) for reinforced versus 5 of 14 patients (36%) for sealed with fibrin glue (p < 0.05). Diameter of residual VSDs accounted for 1.3 +/- 1.2 mm for reinforced versus 0.3 +/- 0.4 mm for sealed with fibrin glue (p < 0.01). Hemodynamically significant residual VSDs were fond in 2 of 22 patients (9%) for reinforced versus 0 of 14 patients (0%) for sealed with fibrin glue (p = not significant). CONCLUSIONS. Small defects sealed with fibrin glue resist physiologic pressure load. Fibrin glue sealing of prosthetic patches during intracardiac VSD repair allows for significant reduction of number and size of residual VSDs. Improved long-term outcome can be expected.
Mots-clé
Anti-Bacterial Agents/therapeutic use Child Child, Preschool Computers Echocardiography Endocarditis/prevention & control Fibrin Tissue Adhesive/administration & dosage/*therapeutic use Follow-Up Studies Heart Septal Defects, Ventricular/*prevention & control/*surgery/ultrasonography Hemolysis Humans Infant Models, Structural Polytetrafluoroethylene Pressure Prospective Studies Prostheses and Implants Single-Blind Method Stress, Mechanical Surgical Wound Dehiscence/prevention & control Survival Rate Suture Techniques Treatment Outcome
Pubmed
Web of science
Création de la notice
14/02/2008 15:16
Dernière modification de la notice
20/08/2019 16:19
Données d'usage