Dynamics of Intraprocedural Dominant Frequency Identifies Ablation Outcome in Persistent Atrial Fibrillation
Détails
ID Serval
serval:BIB_AF5A20C38DB3
Type
Thèse: thèse de doctorat.
Collection
Publications
Institution
Titre
Dynamics of Intraprocedural Dominant Frequency Identifies Ablation Outcome in Persistent Atrial Fibrillation
Directeur⸱rice⸱s
Pruvot Etienne
Codirecteur⸱rice⸱s
Vesin Jean-Marc
Détails de l'institution
Université de Lausanne, Faculté de biologie et médecine
Statut éditorial
Acceptée
Date de publication
2021
Langue
anglais
Résumé
Background: The role of dominant frequency (DF) in tracking the efficiency of a stepwise catheter ablation (step-CA) in persistent atrial fibrillation (peAF) remains poorly studied. We hypothesized that the DF time-course during step-CA displays divergent patterns between patients in whom a step-CA successfully restores long-term sinus rhythm (SR) and those with recurrence.
Methods: This study involved 40 consecutive patients who underwent a step-CA for peAF (sustained duration 19 ± 11 months). Dominant frequency was computed on electrograms recorded from the right and left atrial appendages (RAA; LAA) and the coronary sinus before and during the step-CA synchronously to the 12-lead ECG. Dominant frequency was defined as the highest peak within the power spectrum.
Results: Persistent atrial fibrillation was terminated by a step-CA in 28 patients [left-terminated (LT)], whereas 12 patients remaining in AF after ablation [not left-terminated (NLT)] were cardioverted. Over a mean follow-up of 34 ± 14 months, all NLT patients had a recurrence. Among the 28 LT patients, 20 had a recurrence, while 8 remained in SR throughout follow-up. The RAA and V1 DF had the best predictive values of the procedural failure to terminate AF (area under the curve; AUC 0.84, p < 0.05). A decision tree model including a decrease in LAA DF ≥ 6.61% during the first 20 min following pulmonary vein isolation (PVI) and a baseline RAA DF < 5.6 Hz predicted long-term SR restoration with a sensitivity of 83% and a specificity of 93% (p < 0.05).
Conclusion: This study found that high baseline DF values are predictive of unfavorable ablation outcomes. The reduction of the LAA DF at early ablation steps following PVI is associated with procedural AF termination and long-term SR maintenance.
Methods: This study involved 40 consecutive patients who underwent a step-CA for peAF (sustained duration 19 ± 11 months). Dominant frequency was computed on electrograms recorded from the right and left atrial appendages (RAA; LAA) and the coronary sinus before and during the step-CA synchronously to the 12-lead ECG. Dominant frequency was defined as the highest peak within the power spectrum.
Results: Persistent atrial fibrillation was terminated by a step-CA in 28 patients [left-terminated (LT)], whereas 12 patients remaining in AF after ablation [not left-terminated (NLT)] were cardioverted. Over a mean follow-up of 34 ± 14 months, all NLT patients had a recurrence. Among the 28 LT patients, 20 had a recurrence, while 8 remained in SR throughout follow-up. The RAA and V1 DF had the best predictive values of the procedural failure to terminate AF (area under the curve; AUC 0.84, p < 0.05). A decision tree model including a decrease in LAA DF ≥ 6.61% during the first 20 min following pulmonary vein isolation (PVI) and a baseline RAA DF < 5.6 Hz predicted long-term SR restoration with a sensitivity of 83% and a specificity of 93% (p < 0.05).
Conclusion: This study found that high baseline DF values are predictive of unfavorable ablation outcomes. The reduction of the LAA DF at early ablation steps following PVI is associated with procedural AF termination and long-term SR maintenance.
Mots-clé
atrial fibrillation, catheter ablation, dominant frequency, intracardiac electrogram, surface ctrocardiogram, decision tree model
Création de la notice
18/07/2022 11:11
Dernière modification de la notice
22/09/2022 5:39