16-OR: Investigation of Sharp Trauma and Gunshot Cases Using Post-mortem CT-Angiography

Détails

ID Serval
serval:BIB_AC8CCBA43412
Type
Actes de conférence (partie): contribution originale à la littérature scientifique, publiée à l'occasion de conférences scientifiques, dans un ouvrage de compte-rendu (proceedings), ou dans l'édition spéciale d'un journal reconnu (conference proceedings).
Sous-type
Abstract (résumé de présentation): article court qui reprend les éléments essentiels présentés à l'occasion d'une conférence scientifique dans un poster ou lors d'une intervention orale.
Collection
Publications
Institution
Titre
16-OR: Investigation of Sharp Trauma and Gunshot Cases Using Post-mortem CT-Angiography
Titre de la conférence
Annual Congress of the International Association of Law and Forensic Science (IALFS)
Auteur⸱e⸱s
Grabherr S., Zerlauth JB, Egger C., Mangin P.
Adresse
Dubai, United Arab Emirates, April, 1-3, 2014
Statut éditorial
Publié
Date de publication
2014
Langue
anglais
Résumé
Investigation of violent death, especially cases of sharp trauma and gunshot, is an important part of medico-legal investigations. Beside the execution of a conventional autopsy, the performance of a post-mortem Multi-Detector Computed Tomography (MDCT)-scan has become a highly appreciated tool. In order to investigate also the vascular system, post-mortem CT-angiography has been introduced. The most studied and widespread technique is the Multi-phase post-mortem CT-angiography (MPMCTA). Its sensitivity to detect vascular lesions is even superior to conventional autopsy.
The application of MPMCTA for cases of gunshot and sharp-trauma is therefore an obvious choice, as vascular lesions are common in such victims. In most cases of sharp trauma and in several cases of gunshots, death can be attributed to exsanguinations. MPMCTA is able to detect the exact source of bleeding and also to visualize trajectories, which are of most importance in these cases. The reconstructed images allow to clearly visualizing the trajectory in a way that is easily comprehensible for not medically trained legal professionals. The sensitivity of MPMCTA for soft tissue and organ lesions approximately matches the sensitivity of conventional autopsy. However, special care, experience and effective use of the imaging software is necessary for performing the reconstructions of the trajectory. Large volume consuming haemorrhages and shift of inner organs are sources of errors and misinterpretations.
This presentation shall give an overview about the advantages and limitations of the use of MPMCTA for investigating cases of gunshot and sharp-trauma.
Création de la notice
14/07/2014 11:54
Dernière modification de la notice
20/08/2019 16:16
Données d'usage