Three-dimensional radiobiological dosimetry of kidneys for treatment planning in peptide receptor radionuclide therapy.

Détails

ID Serval
serval:BIB_A890261D6115
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Three-dimensional radiobiological dosimetry of kidneys for treatment planning in peptide receptor radionuclide therapy.
Périodique
Medical Physics
Auteur⸱e⸱s
Baechler S., Hobbs R.F., Boubaker A., Buchegger F., He B., Frey E.C., Sgouros G.
ISSN
0094-2405 (Print)
ISSN-L
0094-2405
Statut éditorial
Publié
Date de publication
2012
Volume
39
Numéro
10
Pages
6118-6128
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, N.I.H., ExtramuralPublication Status: ppublish
Résumé
PURPOSE: Peptide receptor radionuclide therapy (PRRT) delivers high absorbed doses to kidneys and may lead to permanent nephropathy. Reliable dosimetry of kidneys is thus critical for safe and effective PRRT. The aim of this work was to assess the feasibility of planning PRRT based on 3D radiobiological dosimetry (3D-RD) in order to optimize both the amount of activity to administer and the fractionation scheme, while limiting the absorbed dose and the biological effective dose (BED) to the renal cortex.
METHODS: Planar and SPECT data were available for a patient examined with (111)In-DTPA-octreotide at 0.5 (planar only), 4, 24, and 48 h post-injection. Absorbed dose and BED distributions were calculated for common therapeutic radionuclides, i.e., (111)In, (90)Y and (177)Lu, using the 3D-RD methodology. Dose-volume histograms were computed and mean absorbed doses to kidneys, renal cortices, and medullae were compared with results obtained using the MIRD schema (S-values) with the multiregion kidney dosimetry model. Two different treatment planning approaches based on (1) the fixed absorbed dose to the cortex and (2) the fixed BED to the cortex were then considered to optimize the activity to administer by varying the number of fractions.
RESULTS: Mean absorbed doses calculated with 3D-RD were in good agreement with those obtained with S-value-based SPECT dosimetry for (90)Y and (177)Lu. Nevertheless, for (111)In, differences of 14% and 22% were found for the whole kidneys and the cortex, respectively. Moreover, the authors found that planar-based dosimetry systematically underestimates the absorbed dose in comparison with SPECT-based methods, up to 32%. Regarding the 3D-RD-based treatment planning using a fixed BED constraint to the renal cortex, the optimal number of fractions was found to be 3 or 4, depending on the radionuclide administered and the value of the fixed BED. Cumulative activities obtained using the proposed simulated treatment planning are compatible with real activities administered to patients in PRRT.
CONCLUSIONS: The 3D-RD treatment planning approach based on the fixed BED was found to be the method of choice for clinical implementation in PRRT by providing realistic activity to administer and number of cycles. While dividing the activity in several cycles is important to reduce renal toxicity, the clinical outcome of fractionated PRRT should be investigated in the future.
Pubmed
Web of science
Création de la notice
23/10/2012 14:50
Dernière modification de la notice
20/08/2019 16:13
Données d'usage