Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer

Détails

ID Serval
serval:BIB_A7957553177E
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Retinal nerve fiber layer measured by Heidelberg retina tomograph and nerve fiber analyzer
Périodique
European Journal of Ophthalmology
Auteur⸱e⸱s
Iester  M., Mermoud  A.
ISSN
1120-6721 (Print)
Statut éditorial
Publié
Date de publication
04/2005
Volume
15
Numéro
2
Pages
246-54
Notes
Comparative Study
Journal Article --- Old month value: Mar-Apr
Résumé
PURPOSE: To compare retinal nerve fiber layer (RNFL) thickness measured by Heidelberg retina tomograph (HRT) and nerve fiber analyzer (GDx). METHODS: Twenty eyes of 20 consecutive healthy subjects were recruited for this study. Each subject had a normal visual field and a normal optic nerve head, which was assessed by slit-lamp biomicroscopy using a 90 degrees lens. Using the HRT and GDx, RNFL measurement was calculated as for software vs 2.01 and vs 1.0.14, respectively. Retinal nerve fiber layer thickness was evaluated for the entire annulus surface every 5 degrees degrees. RNFL was assessed by HRT and GDx. HRT RNFL measurement was calculated at 0 microm from the edge, while GDx RNFL measurement at 1.75 disc diameter as for software. The difference between the highest points and the deepest points was calculated and compared. Furthermore, because of the possibility of different scales in the two systems, the following ratio was calculated: superior/inferior, superior/temporal, superior/nasal, inferior/temporal, and inferior/nasal. RESULTS: When the entire RNFL thickness was considered, a significant (p<0.001) difference was found between the HRT and GDx measurements. A difference of 200 microm was found between the highest and the deepest HRT points while a difference of 40 microm was found between the highest and the deepest GDx points. CONCLUSIONS: HRT and GDx RNFL measurements were statistically different in each sector. However, ratio parameters showed no difference between the obtained values except for superior/temporal ratio and inferior/temporal ratio.
Mots-clé
Aged *Diagnostic Techniques, Ophthalmological Glaucoma/*diagnosis Humans Lasers/diagnostic use Nerve Fibers/*pathology Ocular Hypertension/diagnosis Retinal Ganglion Cells/*pathology Tomography/methods Visual Fields/physiology
Pubmed
Web of science
Création de la notice
28/01/2008 13:49
Dernière modification de la notice
20/08/2019 16:12
Données d'usage