The Dijon Physical Activity Score: reproducibility and correlations with physical fitness in patients with coronary artery disease

Détails

ID Serval
serval:BIB_A46CDAC8362A
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Titre
The Dijon Physical Activity Score: reproducibility and correlations with physical fitness in patients with coronary artery disease
Périodique
Ann Readapt Med Phys
Auteur⸱e⸱s
Gremeaux V., Lemoine Y., Fargeot A., D'Athis P., Beer J. C., Laurent Y., Cottin Y., Antoine D., Casillas J. M.
ISSN
0168-6054 (Print)
ISSN-L
0168-6054
Statut éditorial
Publié
Date de publication
06/2008
Volume
51
Numéro
5
Pages
366-78
Langue
anglais
Notes
Gremeaux, V
Lemoine, Y
Fargeot, A
D'Athis, P
Beer, J-C
Laurent, Y
Cottin, Y
Antoine, D
Casillas, J-M
eng
fre
Comparative Study
Evaluation Studies
Netherlands
Ann Readapt Med Phys. 2008 Jun;51(5):366-78. doi: 10.1016/j.annrmp.2008.05.003. Epub 2008 Jun 17.
Résumé
OBJECTIVES: To study the clinimetric properties of the Dijon Physical Activity Score (PAS) in patients with coronary artery disease (CAD). PATIENTS: Two populations of patients with CAD: one group of stabilized patients from the RICO county-wide monitoring program and one group in the initial phase of a cardiovascular rehabilitation program (CVR group). METHODS: The patients carried out a maximal effort test on a cycle ergometer, plus two walking tests (a six-minute walk test and a 200 m fast walk test). They completed the Dijon PAS questionnaire on two occasions at an interval of 10 days. The reproducibility of the score and the latter's correlations with physical parameters were analyzed. RESULTS: Sixty-seven subjects were included and 52 answered the questionnaire both times. The average time spent answering the questionnaire was 173+/-37 seconds and reproducibility was satisfactory in the RICO group only. In this group, there were significant correlations between total score and maximal power during the effort test (r=0.41; P<0.05) and between the "sports/leisure activities" sub-score and maximal power (r=0.57; P<0.01). No correlations were found in the CVR group. CONCLUSION: The Dijon PAS is a simple, generic, reproducible and reliable score for measuring physical activity in patients with stable coronary artery disease but, because of the conjunction of confounding factors, it is not suitable for subjects who experienced a recent acute cardiac event. It could thus be used in epidemiological studies to determine the impact of a sedentary lifestyle and the efficacy of methods intended to counter sedentariness and to help design personalized secondary prevention programs.
Mots-clé
Aged, Coronary Disease/*rehabilitation, Exercise, Exercise Test, Female, Humans, Leisure Activities, Life Style, Male, Middle Aged, Physical Fitness, Sports, Surveys and Questionnaires, Time Factors, Walking
Pubmed
Création de la notice
26/11/2019 11:35
Dernière modification de la notice
06/05/2020 5:26
Données d'usage