Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling.
Détails
ID Serval
serval:BIB_99CB3481E52A
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Left ventricular myocardial deformation pattern, mechanical dispersion, and their relation with electrocardiogram markers in the large population-based STANISLAS cohort: insights into electromechanical coupling.
Périodique
European heart journal. Cardiovascular Imaging
ISSN
2047-2412 (Electronic)
ISSN-L
2047-2404
Statut éditorial
Publié
Date de publication
20/10/2020
Peer-reviewed
Oui
Volume
21
Numéro
11
Pages
1237-1245
Langue
anglais
Notes
Publication types: Journal Article ; Research Support, Non-U.S. Gov't
Publication Status: ppublish
Publication Status: ppublish
Résumé
Mechanical alterations in patients with electrical conduction abnormalities are reported to have prognostic value in patients with left ventricular asynchrony or long QT syndrome beyond electrocardiogram (ECG) variables. Whether conduction and repolarization patterns derived from ECG are associated with speckle tracking echocardiography parameters in subjects without overt cardiac disease is yet to be investigated. To report ranges of longitudinal deformation according to conduction and repolarization values in a population-based cohort.
One thousand, one hundred, and forty subjects (48.6 ± 14.0 years, 47.7% men) enrolled in the fourth visit of the STANISLAS cohort (Lorraine, France) were studied. Echocardiography strain was performed in all subjects. RR, PR, QRS, and QT intervals were retrieved from digitalized 12-lead ECG. Echocardiographic data were stratified according to quartiles of QRS and QTc duration values. Full-wall global longitudinal strain (GLS) was -21.1 ± 2.5% with a mechanical dispersion (MD) value of 34 ± 12 ms. Absolute GLS value was lower in the longest QRS quartile and shortest QTc quartile (both P < 0.001). Time-to-peak of strain was not significantly different according to QRS duration although significantly higher in patients with higher QTc (P < 0.001). MD was significantly greater in patients with longer QTc (32 ± 12 ms for QTc < 396 ms vs. 36 ± 12 ms for QTc > 421 ms; P = 0.002).
Longer QTc is related to increased MD and better longitudinal strain values. In a population-based setting, QRS is not associated with MD, suggesting that echocardiography-based dyssynchrony does not largely overlap with ECG-based dyssynchrony.
One thousand, one hundred, and forty subjects (48.6 ± 14.0 years, 47.7% men) enrolled in the fourth visit of the STANISLAS cohort (Lorraine, France) were studied. Echocardiography strain was performed in all subjects. RR, PR, QRS, and QT intervals were retrieved from digitalized 12-lead ECG. Echocardiographic data were stratified according to quartiles of QRS and QTc duration values. Full-wall global longitudinal strain (GLS) was -21.1 ± 2.5% with a mechanical dispersion (MD) value of 34 ± 12 ms. Absolute GLS value was lower in the longest QRS quartile and shortest QTc quartile (both P < 0.001). Time-to-peak of strain was not significantly different according to QRS duration although significantly higher in patients with higher QTc (P < 0.001). MD was significantly greater in patients with longer QTc (32 ± 12 ms for QTc < 396 ms vs. 36 ± 12 ms for QTc > 421 ms; P = 0.002).
Longer QTc is related to increased MD and better longitudinal strain values. In a population-based setting, QRS is not associated with MD, suggesting that echocardiography-based dyssynchrony does not largely overlap with ECG-based dyssynchrony.
Mots-clé
Echocardiography, Electrocardiography, Female, France, Heart Ventricles/diagnostic imaging, Humans, Male, Retrospective Studies, electromechanical coupling, left ventricle, mechanical dispersion, myocardial deformation, population study, speckle tracking echocardiography, systolic function
Pubmed
Web of science
Open Access
Oui
Création de la notice
03/07/2020 17:49
Dernière modification de la notice
09/04/2024 6:13