Reference ranges of oxidative stress biomarkers selected for non-invasive biological surveillance of nanotechnology workers: Study protocol and meta-analysis results for 8-OHdG in exhaled breath condensate.

Détails

Ressource 1Demande d'une copie Sous embargo indéterminé.
Accès restreint UNIL
Etat: Public
Version: de l'auteur⸱e
Licence: Non spécifiée
Document(s) secondaire(s)
Sous embargo indéterminé.
Accès restreint UNIL
Etat: Public
Version: de l'auteur⸱e
Licence: Non spécifiée
Sous embargo indéterminé.
Accès restreint UNIL
Etat: Public
Version: de l'auteur⸱e
Licence: Non spécifiée
ID Serval
serval:BIB_92ECB244D5D9
Type
Article: article d'un périodique ou d'un magazine.
Collection
Publications
Institution
Titre
Reference ranges of oxidative stress biomarkers selected for non-invasive biological surveillance of nanotechnology workers: Study protocol and meta-analysis results for 8-OHdG in exhaled breath condensate.
Périodique
Toxicology letters
Auteur⸱e⸱s
Hemmendinger M., Wild P., Shoman Y., Graille M., Bergamaschi E., Hopf N., Guseva Canu I.
ISSN
1879-3169 (Electronic)
ISSN-L
0378-4274
Statut éditorial
Publié
Date de publication
01/07/2020
Peer-reviewed
Oui
Volume
327
Pages
41-47
Langue
anglais
Notes
Publication types: Journal Article ; Meta-Analysis ; Systematic Review
Publication Status: ppublish
Résumé
In the field of engineered nanomaterials (ENMs) and other airborne particulate exposure biomonitoring, circulating oxidative stress biomarkers appear promising. These biomarkers could be monitored in different biological matrices. Exhaled breath condensate (EBC) enables their measurements in the respiratory tract, without affecting airway function or creating inflammation. The 8-hydroxy-2-deoxyguanosine (8-OHdG) was found increased in the EBC of ENM-exposed workers. Our objectives were to assess the reference range of 8-OHdG in the EBC and to identify determinants of its inter- and intra-individual variability. The meta-analysis was stratified by analytical method (chemical versus immunochemical analysis) and resulted in a between-study variability over 99 % of the total variability. The between-study variability completely dominated the within-studies variability. By using a mixed model with study ID as a random effect rather than a meta-regression, only smoking was evidenced as a potential determinant of 8-OHdG inter-individual variability, and only when immunochemical analysis was used. To our knowledge, this is the first meta-analysis aimed at estimating reference values for 8-OHdG in the EBC. The estimated values should be considered preliminary, as they are based on a limited number of studies, mostly of moderate to low quality of evidence. Further research is necessary to standardize EBC sampling, storage and analytical methods. Such a standardization would enable a more accurate estimation of the reference ranges of the 8-OHdG and potentially other biomarkers measurable in the EBC, which are essential for a meaningful interpretation of the biomonitoring results.
Mots-clé
8-Hydroxy-2'-Deoxyguanosine/chemistry, Biomarkers, Breath Tests, Humans, Nanotechnology, Occupational Exposure, Oxidative Stress, Reference Values, 8-hydroxy-2'-deoxyguanosine, Biomonitoring, Inhalation, Lung inflammation, Occupational exposure
Pubmed
Web of science
Création de la notice
04/04/2020 16:36
Dernière modification de la notice
10/03/2021 7:28
Données d'usage